REFRIGERATION CYCLE DIAGRAMS (CONT)
P
Pressure measurement
Gauge attaching port
Vaccum pump connecting port
Deoxidized copper pipe
{
Outer dia:
0.375
in(
9.52
16
INDOOR UNIT
Cross flow fan
Deoxidized copper pipe
{
Outer dia:
0.25
Sectional shape
of insulation
mm)
Muffler
4-way valve
Muffler
TP
Compressor
Outdoor heat
exchanger
Propeller fan
OUTDOOR UNIT
Fig. 13 — Size 9K - 208/230V
Specifications subject to change without notice.
Indoor heat
exchanger
T2
T1
in(
6.35
mm)
Capillary
Strainer
T4
T3
NOTE: Gas leak check position
Refrigerant flow (Cooling = solid arrow)
Refrigerant flow (Heating = dashed arrow))
Max :
82
ft(
25
m)
Min :
10
ft(
3
m)
Pre-charged:
25
ft(
7.5
m)
Charge :
0.161
oz/ft