Mitsubishi Electric BAC-HD150 Instruction Book page 42

Air-conditioner control system; bm adapter
Hide thumbs Also See for BAC-HD150:
Table of Contents

Advertisement

Control item
Object
Filter Sign Reset
[Circulating Water
BV_xxxx12
Exchange Sign Reset]
(*6)
Prohibition On Off
BV_xxxx13
Prohibition Mode
BV_xxxx14
Prohibition Filter
Sign Reset
[Prohibition Circulating
BV_xxxx15
Water Exchange Sign
Reset] (*6)
Prohibition Set
BV_xxxx16
Temperature
M-NET
Communication
BI_xxxx20
State
BV_xxxx21
System Forced Off
BV_999921
Air Direction Setup
MO_xxxx22
Air Direction State
MI_xxxx23
Set Temp Cool
AV_xxxx24
Set Temp Heat
AV_xxxx25
Status
• Reset the filter sign of the group that detects filter sign
INACTIVE : RESET
ACTIVE : Void
After doing so, check that the filter sign of the group turns to
OFF(INACTIVE) on BMS.
• Prohibit the remote controller (ON/OFF) of the specific
After doing so, check that the remote controller (ON/OFF) of
INACTIVE : Permit
the group turns to (ACTIVE) via the remote controller.
ACTIVE : Prohibit
• Permit the remote controller (ON/OFF) of the specific
After doing so, check that the remote controller (ON/OFF) of
the group turns to (INACTIVE) via the remote controller.
• Operation/checking object is the same as the steps of
INACTIVE : Permit
ACTIVE : Prohibit
• Operation/checking object is the same as the steps of
INACTIVE : Permit
ACTIVE : Prohibit
• Operation/checking object is the same as the steps of remote
INACTIVE : Permit
ACTIVE : Prohibit
• Disconnect M-NET transmission line which is connected
After doing so, check that the M-NET communication status
INACTIVE: Normal
of all groups turns to Error (ACTIVE) on BMS. (*3)
ACTIVE: Error
• Connect M-NET transmission line to BAC-HD150 or
After doing so, check that the M-NET communication status
of all groups turns to Normal (INACTIVE) on BMS.
• Perform a forced stop of the system of the specific group
INACTIVE: Reset
ACTIVE: Execute
After doing so, check that the air conditioner stops on BMS.
01 : Horizontal
• Change the air direction of the specific group from BMS.
02 : Downblow 60%
After doing so, check that the air direction of the group
03 : Downblow 80%
renews the direction using system controller or remote
04 : Downblow 100%
controller.
05 : Swing
01 : Horizontal
• Change the air direction of the specific group using
02 : Downblow 60%
03 : Downblow 80%
After doing so, check that the air direction of the group
04 : Downblow 100%
renews the direction on BMS.
05 : Swing
• Make a setting of set room temperature for cooling of the
°F/°C
• Change the set room temperature for cooling of the
• Make a setting of set room temperature for heating of the
°F/°C
• Change the set room temperature for heating of the
- 42 -
Steps
[ON(ACTIVE)] from BMS. (*2)
group from BMS.
group from BMS.
remote controller (operation mode), but the checking method
is the same as the steps of remote controller (ON/OFF).
remote controller (filter sign reset), but the checking method
is the same as the steps of remote controller (ON/OFF).
controller (set temperature), but the checking method is the
same as the steps of remote controller (ON/OFF).
to BAC-HD150 or PAC-YG50ECA.
PAC-YG50ECA.
from BMS.
system controller or remote controller.
specific group from BMS.
After doing so, check that the set room temperature for
cooling of the group renews the temperature using system
controller or remote controller.
specific group using system controller or remote
controller.
After doing so, check that the set room temperature for
cooling of the group renews the temperature on BMS.
specific group from BMS.
After doing so, check that the set room temperature for
heating of the group renews the temperature using
system controller or remote controller.
specific group using system controller or remote
controller.
After doing so, check that the set room temperature for
heating of the group renews the temperature on BMS.
Result

Advertisement

Table of Contents
loading

Table of Contents