Partition Reporting Codes - IDS X Series Installer Manual

Hide thumbs Also See for X Series:
Table of Contents

Advertisement

LOCATIONS 324 – 327
The 2-digitforce zone arm code is transmitted if a partition is programmed to allow forced arming (arming with a violated zone)
and a zone is violated at the time of arming. Option 4 in Table 41 needs to be enabled.
Each location represents a set of 16 zones:
Location 324 is zones 1-16
Location 326 is zones 33-48
Enter a 2-digit reporting code for each of the 16 zones and program as a 32-digit string, followed by the [*] key.
If any of the sub-locations are disabled here, then the reporting codes will not report
LOCATIONS 328 – 331
The 2-digit swinger shutdown zone code is reported if the system is armed and a zone is automatically bypassed as a result of
multiple violations of that zone. Option 7in Table 41 needs to be enabled.
Each location represents a set of 16 zones:
Location 328 is zones 1-16
Location 330 is zones 33-48
Enter a 2-digit reporting code for each of the 16 zones and program as a 32-digit string, followed by the [*] key.
If any of the sub-locations are disabled here, then the reporting codes will not report
LOCATIONS 332 – 335
The 2-digitzone swinger shutdown restore code is reported when a swinger shutdown zone is automatically restored i.e. un-
bypassed. Option 8 in Table 41 needs to be enabled.
Each location represents a set of 16 zones:
Location 332 is zones 1-16
Location 334 is zones 33-48
Enter a 2-digit reporting code for each of the 16 zones and program as a 32-digit string, followed by the [*] key.
If any of the sub-locations are disabled here, then the reporting codes will not report
Note: The following locations valid data ranges are: 01-FF, with 00 to disable.Partition no. is: 1-8.
LOCATION 336
Duress Reporting Code
The 2-digit duress code is reported when a duress code is entered into any keypad belonging to the specified partition.
Option 1 in Table 47 needs to be enabled.
Enter a 2-digit reporting code for each of the 8 partitions and program as a 16-digit string, followed by the [*] key.
[INSTALLER CODE] [*] [3] [3] [6] [*] [PARTITION NO.] [*] [REPORTING CODE] [*]
If any of the sub-locations are disabled here, then the reporting codes will not report – even if enabled
LOCATION 337
Keypad Panic Reporting Code
This location is configured per partition. This 2-digit code is reported when the [P] key on any keypad belonging to the specified
partition is held down for two seconds. Option 2 in Table 47 needs to be enabled.
Enter a 2-digit reporting code for each of the 8 partitions and program as a 16-digit string, followed by the [*] key.
If any of the sub-locations are disabled here, then the reporting codes will not report – even if they are enabled
LOCATION 338
Fire Reporting Code
The 2-digitfire code is reported when the [F] key on any keypad belonging to the specified partition is held down for two seconds.
Option 3 in Table 47 needs to be enabled.
Enter a 2-digit reporting code for each of the 8 partitions and program as a 16-digit string, followed by the [*] key.
If any of the sub-locations are disabled here, then the reporting codes will not report – even if they are enabled
LOCATION 339
Medical Reporting Code
The2-digitmedical code is reported when the [M] key on any keypad belonging to the specified partition is held down for two
seconds. Option 4 in Table 47 needs to be enabled.
Enter a 2-digit reporting code for each of the 8 partitions and program as a 16-digit string, followed by the [*] key.
If any of the sub-locations are disabled here, then the reporting codes will not report – even if enabled
36
Zone Force Arm Reporting Code
[INSTALLER CODE] [*] [LOCATION] [*] [ZONE NO.] [*] [REPORTING CODE] [*]
Zone Swinger Shutdown Reporting Code
[INSTALLER CODE] [*] [LOCATION] [*] [ZONE NO.] [*] [REPORTING CODE] [*]
Zone Swinger Shutdown Restore Reporting Code
[INSTALLER CODE] [*] [LOCATION] [*] [ZONE NO.] [*] [REPORTING CODE] [*]

Partition Reporting Codes

[INSTALLER CODE] [*] [3] [3] [7] [*] [PARTITION NO.] [*] [REPORTING CODE] [*]
[INSTALLER CODE] [*] [3] [3] [8] [*] [PARTITION NO.] [*] [REPORTING CODE] [*]
[INSTALLER CODE] [*] [3] [3] [9] [*] [PARTITION NO.] [*] [REPORTING CODE] [*]
IDS X-Series Installer Manual 700-398-02O
Location 325 is zones 17-32
Location 327 is zones 39-64
Location 329 is zones 17-32
Location 331 is zones 39-64
Location 333 is zones 17-32
Location 335 is zones 39-64

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents