Page 4
Programmable Output Options ---------------------------------------------------------------- 56 Keypad Options------------------------------------------------------------------------------------58 Installer Options-----------------------------------------------------------------------------------59 Index of Programming Locations --------------------------------------------------------------------- 60 Index -----------------------------------------------------------------------------------------------------------63 IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 5
Table 9 : Value for Day of the Week------------------------------------------------------------------ 35 Table 10 : Standard Contact ID Reporting Codes ---------------------------------------------- 39 Table 11 : Standard SIA Reporting Codes --------------------------------------------------------- 40 Table 12 : User Codes ------------------------------------------------------------------------------ 52 IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 6
IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 7
IDS 1632 Installer Manual 700-256-02K Issued September 2009...
The IDS 1632 also interfaces to a Voice Module, GPRS module and may be controlled remotely via DTMF telephone keypad. The voice module makes it possible to have the Alarm Panel call a user’s telephone number and report in plain English.
Page 9
Support for secure dial-in functionality using any DTMF phone. Optional voice module for voiced reporting and DTMF, voice-prompted remote-controlled menu. GPRS SMS reporting and alarm control functionality via cellphone (when a GSM Communicator is installed). IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Sire n 4 A Direct Dowload Port Radio Tran smitte r / Commu nicato r P owe r Zone Panic Door LED Button +12V Battery 4A Aux 1A 16V AC AC Mains IDS 1632 Installer Manual 700-256-02K Issued September 2009...
AND zone violation will be reported. Panic zones always register panic and tamper conditions. The colour codes for the 12K and 4K7 resistors are as per in Figure 4. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
3 above zone 16 would indicate the violation. The colour codes for the 4K7 and 12K resistors are shown in Figure 4. Figure 4 : Resistors (Tamper per Zone or Zone Doubling) IDS 1632 Installer Manual 700-256-02K Issued September 2009...
The box tamper input does not require an end-of-line resistor and requires a normally closed contact. Installing an Expander Module When installing an expander module refer to the document supplied with the module. Note that only one or two (8-zone) expansion modules may be added to the IDS 1632 Alarm Panel. Connecting the Telephone Communicator Refer to Figure 1.
AC power. Release the reset switch approximately 2 seconds after reapplying the power. Factory default values will now be restored to all locations and all attached keypad IDs will be defaulted. A default event will be logged and the existing event log will NOT be erased.
Additional Devices To enrol other devices (IDS Remote Receivers or Zone Expanders); consult the installation instructions for those devices. The IDS 1632 Alarm Panel can accept up to two eight-zone expander modules, and an IDS Remote Receiver. Replacing a Faulty Keypad/Device...
1-4 indicate units (1’s) and zone indicator 5-8 indicate tens (10’s), and so on. To read a binary value on the keypad sum the values represented by each on LED as shown in Table 1: IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Extended locations that are double tiered and have sub-locations. Both standard and extended locations may contain further subcategories referred to as bitmapped locations. For both main categories, clear visual keypad prompts are provided which aid the programming process. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
ARMED and AWAY indicators will come on. Enter the [NEW DATA] followed by the [*] star key. A long beep will indicate a valid entry. The AWAY indicator will turn off. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
There is no need to press the [#] hash key. In the case of extended locations, the AWAY and ARMED indicators will remain on after the error beeps. Re-enter the correct data. There is no need to press the [#] key. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Action Will reset all locations to the factory default values. (Master User Code 1234) and all keypad IDs will be defaulted. Will default the master user code to 1234 - or 123456 if 6 digits are being used. Master user code properties will also be defaulted.
This zone type CANNOT be bypassed. INSTANT ZONE When the panel is armed, the violation of an instant zone will cause the control panel to register an alarm condition. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 22
The Cross-Zone Delay Timer is started. See Location 36. Depending on the value programmed into location 37 (Cross-Zone Trip Count), the zone (or any other zone with cross-zone option enabled) must trip the number of times programmed into location IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 23
The tamper code will be reported if tamper-by-zone has been enabled and a zone tamper occurs. Sub-location 8 Tamper Restore Reporting Code When a zone tamper condition clears, this code will be reported. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
The zone loop response is the period of time for which the programmed zone must remain violated before a violation is registered. Unless the Second Loop Response Time is selected, this location will determine the response time. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 25
Program a value from [0] to [1] [5]. A [0] will disable this location. Program zones as cross-zones in sub- location 2 of locations 1 to 16. Any single zone enabled for cross zoning, which is violated continuously for the time specified in Location 36 will also register an alarm condition. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 27
Provided the back up battery is in good condition, short AC power failures will not affect the functioning of the alarm system. Select the appropriate value from the table above. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 28
The trouble condition can be viewed by holding down the [7] key for three seconds. See “Viewing Trouble Conditions” in the user manual. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 29
The keypad will remain locked for the time programmed in Location 44. Activating a Keypad Panic (or Medical or Fire Emergency) will unlock the keypad. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
The control panel will transmit this code once the AC restore delay time has elapsed. (See location 39). It will however only be reported if an AC failure was registered as per location 47. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 31
This reporting code will be reported if a jamming signal is detected by the RF receiver module for a period exceeding 30 seconds. LOCATION 62 RF Jamming Restore Reporting Code This reporting code will be reported once the jamming signal has ceased for a period exceeding 30 seconds. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
For these events, only a single digit code need be programmed. There are eight programmable outputs on the IDS 1632 Alarm Panels and a further two programmable outputs on each of the optional Wired Zone Expander modules. When selecting outputs, programmable outputs on the Alarm Panels are addressed from “1”...
Function Driven Programmable Outputs Table 8 : Function Driven Programmable Outputs Summary of System function Driven Programmable outputs Loc. Function Output Fire Sensor Power Programmable Output Disabled Dual Reporting Programmable Output Disabled IDS 1632 Installer Manual 700-256-02K Issued September 2009...
LOCATION 101 System Year Enter the current year as a four digit value e.g. 2007. LOCATION 102 System Day of Week Enter the current day of the week. Refer to table below. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
(5). LOCATION 109 Daylight Saving Time Offset This location is used for setting the Daylight Saving offset. Enter the number of minutes the clock will offset - Valid range 0 to 250. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
When programmed for single reporting, the panel default will alternate attempts between the two “equally ranked” stored numbers. With LED 4 on, the secondary number will only be called if the IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 37
Number of Dial Attempts (Default = 6) This location determines the maximum number of dial attempts that the panel will make in order to contact the base station. NOTE: Entering [0] into this location will disable the dialler. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 38
When dual reporting is enabled, it is possible to select two different formats. In this instance all data will be transmitted to each phone number (i.e. reported twice) using a different format per phone number. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
If this is not done, the panel will keep calling that same number for the number of times stored in location 115 (number of dial attempts). NOTE: If the system is armed using the quick arm key [1] the system will report a close by user 35. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Line Tamper Restore Entry Alarm Enabling / Disabling Reporting Groups Locations 118 to 120 are used to either enable or disable the reporting of groups of reporting codes when using Contact ID, or SIA. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
[MODE] [3]) will provide a 12 second pause and a value of [15] (by pressing [MODE] [5]) will provide a 4 second pause. To terminate a telephone number, program a [0] immediately after the last digit of the telephone number. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
If forced answer is enabled the [8] key may be used to force the panel to go off hook, “answering the line”. If enabled, Auto Pickup will pick up the line after the number of rings programmed into location 124. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
LOCATION 125 Call-back Phone Number If Call-back is enabled in Download Options (Location 123) the phone number programmed into this location will be used to respond to a call-back request from the IDS Download Software/PC. 11.4 Cellphone Operation Settings LOCATION 126...
2. Sub-location 2 Primary Account Code This account code is used if single reporting has been enabled. If dual reporting is enabled then this account code is reported to telephone number 1. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 47
With this option enabled, the panel will arm with violated zones e.g. an open window. When the panel arms, any violated zone is bypassed. If bypassed zones restore during the arm cycle (a window is closed, for example), the zone is automatically re-activated (un-bypassed). IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 48
(Values identical to Sub-location 6) This entry delay begins after the violation of a primary entry/exit zone. During this period, it is permissible to violate follower zones without causing an alarm condition provided that an entry/exit zone was violated first. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 49
11. LED’s Days of the Week LED 1 Monday LED 2 Tuesday LED 3 Wednesday LED 4 Thursday LED 5 Friday LED 6 Saturday LED 7 Sunday All OFF (Auto Arm Disabled) IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 50
This code is reported when a duress code is entered. Sub-location 17 Keypad Panic Reporting Code This code is reported when the [P] key on a keypad is held down for two seconds. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 51
Burglary Programmable Output Pulse High [2] Panic Programmable Output Pulse High [2] Fire Programmable Output Disabled Tamper Zone Programmable Output Disabled Siren Programmable Output Disabled Strobe Programmable Output Disabled Chime Programmable Output Disabled IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Wired Zone Expander 1 - Programmable Output 1 User Options LOCATIONS 136 – 385 Individual User Code Setup The IDS 1632 panels provide for 250 user codes. These locations allow the installer to configure the user code properties. Table 12 : User Codes Loc Number...
Page 53
User 61 User 186 User 62 User 187 User 63 User 188 User 64 User 189 User 65 User 190 User 66 User 191 User 67 User 192 User 68 User 193 IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 54
User 112 User 237 User 113 User 238 User 114 User 239 User 115 User 240 User 116 User 241 User 117 User 242 User 118 User 243 User 119 User 244 IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 55
The exception to this rule is when using domestic reporting where only the first digit is used. Sub-location 3 Close Reporting Code This code is reported when the panel is AWAY ARMED. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 57
(0100 for 1 am, for example). Sub-location 5 Schedule OFF Days This bitmapped sub-location determines on which day(s) an output will be scheduled to RESET. Days of the Week Monday Tuesday Wednesday Thursday Friday Saturday Sunday IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Enable Keypad Zone Disable Keypad Zone RESERVED RESERVED Keypad is an ARMING Keypad RESERVED RESERVED RESERVED Page two Zones Status (Zones 17 to 32 displayed) Page one Zones Status (Zones 1 to 16 displayed) IDS 1632 Installer Manual 700-256-02K Issued September 2009...
For the detailed operation of this switch, refer to Section 12: Hardware Reset Switch. LOCATION 445 Installers Code (Default = 9999) Enter the installer code into this location. LOCATION 446 View Keypad ID View the data in this location to ascertain the Keypad ID. IDS 1632 Installer Manual 700-256-02K Issued September 2009...
System Year ------------------------------------------------------------ 34 LOCATION 102 System Day of Week ------------------------------------------------- 34 LOCATION 103 Month to Start Daylight Saving ---------------------------------- 35 LOCATION 104 Day of Week to Start Daylight Saving ------------------------- 35 IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Defaulting Keypads ............................15 Defaulting of the Panel or Master User Code ....................20 Device Tamper Reporting Code ........................31 Devices (Enrolling) ............................14 Disabled Zone ..............................21 Domestic Reporting (Notes) ..........................39 IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 64
Keypad Bus ..............................14, 31 Keypad Bus Failure Reporting Code ......................31 Keypad Fire Reporting Code (Explanation) ....................51 Keypad Lockout Count ............................ 29 Keypad Lockout Reporting Code (Explanation) ..................... 51 Keypad Lockout Time ............................30 IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 65
Programmable Zone Loop Response Time ....................24 Programmable Zone Types ..........................21 Programming a Bitmapped Location ......................19 Programming Extended Locations ........................18 Programming Location Summary ........................20 Programming Standard Locations ........................18 Programming Telephone Numbers ......................... 43 IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 66
System Time ..............................34 System Year ..............................34 Tamper by Zone ............................... 22 Tamper Reporting Code ..........................23 Tamper Restore Reporting Code ........................23 Tamper Zone ..............................22 Telephone Communicator - Connecting......................13 IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 67
Warning Zone ..............................22 Wiring ................................10 Zone Doubling ..............................12 Zone Name Editing ............................24 Zone Properties ..............................22 Zone Reporting Codes ............................. 23 Zone Shutdown Count ............................. 24 Zone Type ................................. 20 IDS 1632 Installer Manual 700-256-02K Issued September 2009...
Page 68
IDS 1632 Installer Manual 700-256-02K Issued September 2009...