Advertisement

IDS
Users Guide to Keypad
Functions
MANUAL NO. 700-146-01D ISSUED NOVEMBER 2002
VERSION 2.17

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IDS1600 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IDS IDS1600

  • Page 1 Users Guide to Keypad Functions MANUAL NO. 700-146-01D ISSUED NOVEMBER 2002 VERSION 2.17...
  • Page 2 + [     ] + + [     ] + + [     ] + + [     ] + IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 3: Table Of Contents

    7.3 To Disarm with a Key-Switch or Remote Control ....... 23 Emergency Situations ............23 8.1 Fire Alarm .................. 23 8.2 Panic Alarm ................24 8.3 Medical Alarm ................24 8.4 Duress Code ................24 IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 4 16. Trouble-Shooting ..............44 16.1 Trouble Conditions ..............44 16.2 Problems When Arming the System ......... 44 16.3 Problems when disarming the system ........45 16.4 For Service ................45 IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 5: Glossary

    Stay Zone Zones which are bypassed automatically when the system is STAY ARMED. Zone A specific area of your premises guarded by sensors which detect violations of that area. IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 6: Introduction To The Ids1600

    IDS1600 USER MANUAL 1. Introduction to the IDS1600 The IDS1600 Control Panel is manufactured to the highest specifica- tion and will provide many years of service if correctly installed and maintained. The unit is designed for simple operation yet provides the maximum protection for you, your family or business.
  • Page 7: Understanding The Led Keypad Indicators

    Indicator (Red) TROUBLE u l l t i t Indicator (Green) READY u l l i t r o i t ZONE Indicators (Yellow) u l l IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 8: Notes On The Lcd Keypad

    L.E.D.’s. The keypad is used to send commands to the system and to display the current system status. The keypad(s) will be mounted in a convenient location within IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 9: System Information

    Stay Arm and Go Siren Sound on Arm/Disarm (double toot - arm/ short toot - disarm) Panic Alarm Fire Alarm Medical Alarm Chime Zones Buzz Zones Zone Tamper Monitoring Remote Arm and Disarm IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 10: User Codes

    IDS1600 USER MANUAL 4.2 User Codes t i t 3 4 5 6 X X X X X X X X IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 11 IDS1600 USER MANUAL t i t 3 4 5 6 IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 12: Zone Information

    IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 13: Arming The System

    [#] key and re-enter the code. The ARMED indicator will flash for the duration of the exit delay. Any bypassed zones will be shown by a steady illuminated zone indicator. IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 14: Quick Away Arming

    0 1 / 0 1 / 9 9 0 : 0 4 R E A D Y M O N IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 15: Quick Stay Arming

    (Hold down the key until the keypad buzzer sounds) This is a quick function which allows the user to STAY arm and leave the premises. Hold down the [6] key until the keypad buzzer sounds. The IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 16: Arming A Partition From A Master Keypad

    Should the violated zone not be assigned to the current partition, arming of the current partition can still take place. IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 17: Arming From A Key-Switch Or Remote Control

    This means that a monitored window can be left open or other zones can be violated and the panel will still arm. If the violated zone is then cleared, the zone will remain bypassed for the duration of the arm cycle. IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 18: Zone Bypassing

    6.1.1 Bypassing Zones using the LCD Keypad Hold down the [9] key until the keypad sounds. B Y P A S S M O D E Press the [ MODE/ menu > ] key. IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 19 Press [#] to exit the main menu. R E A D Y 0 : 0 4 Z O N E If multiple zones have been bypassed, e.g. zones 3 and 5, the IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 20: To Un-Bypass A Zone

    B Y P A S S Use the [ MODE/ menu > ] and [ FIRE/ < menu ] keys to scroll to the zone you wish to un-bypass e.g. zone 3. IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 21: Disarming The System

    M O N 7. Disarming the System 7.1 Disarming with a User Code [#] + [USER CODE] To disarm the system, enter a valid [ USER CODE ] before the expiry of IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 22: Disarming A Partition From A Master Keypad

    Hold down the [ MODE ] key on a master keypad until the keypad buzzer sounds. P A R T I T I O N : Enter the [ PARTITION NUMBER ] you wish to arm followed by the IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 23: To Disarm With A Key-Switch Or Remote Control

    The siren will sound and the FIRE REPORTING CODE will be transmitted to the monitoring company. To silence the siren enter a 4 digit [ USER CODE IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 24: Panic Alarm

    It is advisable to choose a code that can be easily remembered by all family (or staff) members. IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 25: Emergency Evacuation Plan

    W A S V I O L A T E D The bypassed zones will have constantly illuminated indicators. The memory status will be displayed for five seconds, or until the IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 26: User Codes

    ] and press the [] key. USER CODE Repeat steps 5-6 to enter or change other user codes. Once all the codes are programmed, press the [#] key to exit. IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 27 C O D E : Enter the new 4 digit [ ] and press the [] key. USER CODE C O D E N U M B E R : IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 28: Deleting User Codes - Led Keypad

    Hold down the [3] key until the keypad buzzer sounds. Press the [ ] corresponding to the zone you wish to be a NUMBER zone followed by the [] key. STAY IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 29 Press the [] key to make the zone a stay zone. Z O N E D E S E L E C T Repeat steps 3 and 4 until stay zones are selected. IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 30: To Cancel The Stay Zones

    [] key. The relevant zone indicator will extinguish. Press the [#] key to exit the stay zone programming mode. NOTE: The system will automatically exit this mode after 60 seconds. IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 31 Z O N E Repeat steps 3 and 4 until required stay zones are cancelled. Press [#] to exit the Stay Zone Mode. Z O N E M E N U IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 32: Buzz Zones

    Section 12. A Stay zone cannot be selected as a Buzz zone; the Stay status must be cleared first). Repeat steps 1-3 until all the required Buzz zones are programmed. Press the [#] key to exit the buzz programming mode. IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 33 D E S E L E C T Repeat steps 3 and 4 until buzz zones are selected. Press [#] to exit the Buzz Zone Mode. Z O N E M E N U IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 34: To Cancel Buzz Zones

    B U Z Z M O D E Press the [ MODE/ menu > ] key. Z O N E F O R B U Z Z Z O N E IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 35 M E N U Press [#] to exit the Main Menu. 0 1 / 0 1 / 9 9 0 : 0 4 R E A D Y M O N IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 36: Chime Zones

    C H I M E M O D E Press the [ MODE/ menu > ] key. Z O N E F O R C H I M E Z O N E IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 37 M E N U Press [#] to exit the Main Menu. 0 1 / 0 1 / 9 9 0 : 0 4 R E A D Y M O N IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 38: To Cancel The Chime Zones

    D E S E L E C T Press the [] key to cancel the chime zone. Z O N E F O R C H I M E Z O N E IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 39: Lcd Keypad Menu Navigation

    > Fire/ < menu items and press [] to select a menu item. NOTE: Please see overleaf for diagram illustrating the LCD keypad menu structure. IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 40 4 Zone Names 3 Assign User Codes 4 Set Date and Time 5 Stay Arm 6 Stay Arm & Go 7 Reset Fire Sensor 8 Answer Phone # To Exit Menu IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 41: View Menu

    This menu option allows the user to change zone modes. 15.4.1 Chime Zones Shortcut key - The chime mode allows the user to monitor nominated zones while the system is disarmed. The keypad buzzer will sound briefly when the IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 42 15.4.5 Zone Names This option is used for description purposes i.e. instead of showing a zone 3 violation, “zone 3” would be repaced by the description programmed here, eg. “kitchen”. IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 43: Assign User Codes

    IDS1600 USER MANUAL 15.5 Assign User Codes The IDS1600 has 64 programmable user codes. See page 24 for instructions on programming, deleting and changing user codes. 15.6 Set Date and Time This menu option allows the user to set the time and date on the panel.
  • Page 44: Trouble-Shooting

    If you enter the wrong user code, there will be no response from the system. Does the code belong to that partition? Check the user code table to see to which partition your code is IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 45: Problems When Disarming The System

    The panel will not disarm? You may have entered an incorrect code. Press the [#] key first, then re-enter your user code. 16.4 For Service Central Station Information: Installer Information: IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 46 LCD ....8, 18, 20, 27, 28, 29, 31, 33, 34, 36, 38, 39 LED ................. 7, 8, 28 Keyswitch ................17, 23 Master Keypad ................16, 22 Master User Code ............. 10, 26, 27 IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...
  • Page 47 Entry / Exit ........... 5, 9, 14, 16, 17, 22, 45 Follower ............5, 9, 14, 16, 17, 45 Instant .................. 5, 45 Panic ..................18 Stay ........ 5, 15, 16, 28, 29, 30, 31, 32, 40, 42 IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17...

This manual is also suitable for:

Ids1200

Table of Contents