ARMING SYSTEM WHEN STAYING AT HOME
Wait for green 'Ready' light to come on
Press and hold down 5 key until you hear a beep
The armed Red light will come on.
ARMING WHEN LEAVING THE HOUSE
Wait for green 'Ready' light to come on
Press '#' an enter your user code.
The red 'Armed' light will come on exit delay beeps should now begin, you may now
exit.
DISARMING
Enter your user code
Should you make a mistake press the hash Key (#) and re-enter your user code.
BYPASSING OF ZONES
Confirm panel is DISARMED
Press the [*] key (while bypassing zones, violated zones will be flashing0.
Press the number corresponding to the zone you need to bypass e.g. the [2] key if you
wish to bypass zone 2.
Repeat steps 1 and 2 to bypass any other zones.
OR
Confirm panel is DISARMED
Hold [9] till beep
Press the number corresponding to the zone you need to bypass then star [*], e.g. the
[2] key if you wish to bypass zone 2.
NOTE: Bypassed zones will be cleared when system is disarmed.
TROUBLE CONDITIONS
If the POWER LED is flashing (or if so programmed, the keypad is beeping) hold down the [7] key
for one second to see which zone indicator is on
Indicator
2
3
4
5
6
7
8
Note: if the trouble has been fixed pressing the [#] key within 5 seconds of entering the
trouble view will clear the trouble condition indicator.
Trouble Condition
Failure to communicate to monitoring company
Mains power failure
Low battery
The telephone line has been cut or is not present
The siren wire has been cut or the fuse has blown
Keypad has experienced a tamper
Installers code must be entered to clear an alarm condition
Need help?
Do you have a question about the X64 and is the answer not in the manual?