Changing A Partition; Output Control Via A Keypad; Table 3 Trouble Conditions - IDS 1632 User Manual

Ids 1632 alarm system user manual
Hide thumbs Also See for 1632:
Table of Contents

Advertisement

Table 3 : Trouble Conditions
Indicator
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
19.
To change partitions the keypad must be a global keypad.
1.
Ensure that the Panel is disarmed
2.
Hold [MODE] until the keypad beeps.
3.
Press [1] [*] followed by the [Partition Number] [*].
If no key is pressed on the keypad for specified delay period (default is 20 seconds), the keypad will
beep and default back to its original partition. The keypads may be programmed to remain in the new
partition. (Ask your Installer about this option). Entering partition numbers other than those in the range 1
to 8 will produce a key entry error.
20.
If the panel has been set up to control switching functions via its outputs, these can be controlled via the
keypad - e.g. turning lights on and off.
Hold down the [MODE] key and press [3] [*].
(Any outputs that are currently set [ON] will be shown as an on zone indicator.)
To toggle the output status, enter [OUTPUT NUMBER] followed by [*]. Press [#] to exit User Program
Mode.
Ensure that you have checked with your installer which outputs are used for radio reporting so
as to prevent the triggering of false alarms.
24
Trouble Condition
AC Mains Failure
Failure to communicate successfully to monitoring company
Phone line trouble
Siren tamper
Low battery
Loss of Clock Timer
Engineer Reset
Box tamper
n/a
Tamper on peripheral device
Communication loss to peripheral device
Loss of power to peripheral devices
Reserved
SIM PIN Trouble
Low Airtime

Changing a Partition

Hold down the [MODE] key until the beep,
then enter [1] [*] [Partition Number] [*]

Output Control via a Keypad

IDS 1632 User Manual 700-256-01I Issued March 2009