Do you have a question about the X Series and is the answer not in the manual?
Questions and answers
Andries
February 20, 2025
how to set time and date on IDS X series
1 comments:
Mr. Anderson
May 14, 2025
To set the time and date on the IDS X Series:
1. Ensure the panel is not armed. 2. Hold down the [*] key until the keypad buzzer sounds. 3. When the display shows "Master Code + *", enter the MASTER USER CODE (default is 1234 or 123456), then press [*]. 4. Use the [PANIC] or [MED] keys to scroll through menu options. 5. Select Option 40 to edit the time. 6. Select Option 41 to edit the date.
Alternatively, if time updates are enabled, the system can automatically retrieve time and date from the cell network once a week via SMS.
Contents Introduction to the IDS X-Series LCD Digital Keypad .............. 7 Viewing Violated Zones ......................7 Arming the Control Panel ......................8 Away Arming ..........................8 3.1.1 How to Away Arm ........................8 3.1.2 Quick Away Arm - Shortcut Key ....................8 Stay Arming ..........................
Page 4
Table 4: Output Actions Data ........................20 Table 5: Enable User Reporting Codes ..................... 21 Table 6: Specify which Telephone Module to use ..................21 Table 7: Trouble Conditions ........................26 IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
Page 5
IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
Page 6
IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
The above figure shows that zones 2, 23, and 24 have been violated. The display options are [1] for LCD mode with the scrolling text, or [2] for LED mode. IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
30 seconds before sounding the siren. Entering a valid user code before the siren sounds, prevents an alarm condition from being registered and will silence the keypad buzzer and prevent the siren from sounding. IDS X64 LCD Keypad User Manual 700-411-01C Issues August 2010...
A beep will sound to indicate successful selection of a profile. Program STAY and BUZZ zones for the profile (see sections 9 and 10), and/or ARM the profile (with the [5] key). IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
[USER CODE] entered during the pre-arm delay will terminate the arming sequence. The pre-arm delay is signalled by an exit beep. IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
Ensure the panel is not armed. To enter bypass mode, hold down [9] until the beep. The LCD display reads „User Code + *‟. Enter the [USER CODE] followed by the [*] key. IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
(Hold down the [M] key for two seconds until the keypad buzzer sounds) If the [M] key is pressed until the keypad beeps (approximately 2 seconds) a MEDICAL ALARM condition will be activated. IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
(with the [PANIC] key) then just events up to and including this reference point will be viewable. If no event is encountered then the second line will appear as IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
The first number is the partition number within which the event occurred. The second number will either be the zone or user number associated with the event type. Below is an example of how an event will be displayed on the two-line IDS LCD keypad. “02:00 01/01/2010”...
[*] [MASTER CODE] [*] [1] [*] [OLD CODE] [*] [NEW CODE] [*] [#] Enter the User Program Mode as per steps 1 - 4 of section 8.2. The LCD display reads „Option Menu‟, „Add User Code‟. IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
[*] [MASTER CODE] [*] [4] [*] [SLOT NUMBER] [*] [#] Enter the User Program Mode as per steps 1 - 4 of section 8.2. The LCD display reads „Option Menu‟, „Add User Code‟. IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
Press the [#] key twice to exit User Program Mode. EXAMPLE: To enable a User Code to function as a duress code, when prompted for the option press the [2] key followed by the [*] key. IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
This code will disarm the partitions assigned to the user depending on their status. If all partitions are armed, entering a group code will disarm all of the assigned partitions. In a case where some partitions IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
To select menu option 13 –„User Outputs‟, press the [1] [3] keys or alternatively use the [PANIC] or [MED] keys to scroll through the list of programmable options until you reach the option you want. Press the [*] key. IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
To select menu option 14 – „User RC Enable‟, press the [1] [4] keys or alternatively use the [PANIC] or [MED] keys to scroll through the list of programmable options until you reach the option you want. IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
Press the [*] key to toggle between ON and OFF. Press the [#] key to exit the User Program Mode. Table 6: Specify which Telephone Module to use On / Off Action Telephone Module 2 IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
Press the [#] key to exit the User Program Mode. NOTE: When you are at step 6, entering a zone number, you can use the following options to copy or delete a zone name: IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
2 by holding the [5] key for two seconds. STAY and BUZZ zones can be programmed for each profile once the profile has been selected. See sections 9 & 10. IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
If it is not programmed as a buzz zone, the alarm will be triggered immediately. If the panel was armed using the [6] key (Stay Arm and Go) violation of the Entry/Exit zone will always start the Entry/Exit delay. IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
Press the [*] key to toggle between YES and NO. Repeat steps 3 - 5 until all the required Chime zones are programmed/cancelled. Press the [#] key to exit the Chime zone programming mode. IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
The LCD display reads „P(number)‟. The keypads may be partitioned to remain in the new partition. Any value outside of these constraints will result in a key entry error occurring. IDS X-series LCD Keypad User Manual 700-411-01D Issues August 2010...
Repeat steps 5 – 6 to program any other outputs. Press the [#] key to exit. Ensure that you have checked with your Installer which outputs are used for radio reporting to prevent the triggering of false alarms. IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
Page 28
IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
Page 29
IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
Page 30
IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
Page 31
8 = Box Tamper View Trouble Conditions 9 = Tamper on Peripheral Device 10 = Comms Loss to Peripheral Device 11 = Loss of Power to Peripheral Device 12 = EEPROM Failure IDS X-series LCD Keypad User Manual 700-411-01C Issues August 2010...
Page 32
IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010...
Need help?
Do you have a question about the X Series and is the answer not in the manual?
Questions and answers
how to set time and date on IDS X series
To set the time and date on the IDS X Series:
1. Ensure the panel is not armed.
2. Hold down the [*] key until the keypad buzzer sounds.
3. When the display shows "Master Code + *", enter the MASTER USER CODE (default is 1234 or 123456), then press [*].
4. Use the [PANIC] or [MED] keys to scroll through menu options.
5. Select Option 40 to edit the time.
6. Select Option 41 to edit the date.
Alternatively, if time updates are enabled, the system can automatically retrieve time and date from the cell network once a week via SMS.