CORNER FLOOR PROTECTORS (Hearths)

While the information in the previous section details the MINIMUM size of floor protector necessary
to comply with the Safety Standards, it may often be desirable to use a somewhat larger size for
aesthetic reasons. A particular example is when the woodfire is installed diagonally in a corner. A
neater appearance will result if the floor protector is carried right into the corner and is shaped as
shown below. The chart facilitates calculation of the MINIMUM dimensions required for floor
protectors of this shape. Minimum allowable values for dimension 'E' are given in the tables on pages
4 and 5.
E
MINIMUM DIMENSIONS — mm
See pages 6, 8 for construction.
LE 2000
LE 3000 Series 2
LE 5000
Panorama Series 3
Grandview
Your measurement 'E' must be added to 'X' and 'Y' to find the appropriate minimum overall
floor protector dimensions. See page 4 or 5 for minimum values of 'E'.
Increase 'Y' by 120mm if the floor protector top is not at least 50mm above the floor.
Y
Horizon,
Without Shelf
Siena
Series 2
Without Shelf
Verona
Toronto
Without Shelf
Y
X
AUSTRALIA
X
With Shelf
880
880
980
With Shelf
980
980
970
With Shelf
1025
980
1100
7
E
X
Corner Floor
Prot ect or
Arrangement
NEW
ZEALAND
Y
X
880
565
560
600
880
600
650
605
1035
605
950
570
605
655
970
655
1015
640
625
675
655
1050
890
725
1250
Y