Positioning - Masport LE 3000 2 Series Owner's Manual & Installation Manual

Table of Contents

Advertisement

POSITIONING YOUR FREE-STANDING WOODFIRE
Free-standing woodfires must not be installed in a fireplace or alcove, or under a ceiling of not less
than 2.3m. No wall or other fixed object may be closer to the front of the woodfire than one metre.
If a water heating accessory is to be fitted, a further positioning restraint is the need to be close to
your hot water storage cylinder (See page 10).
Finalise the installation position for your woodfire only after considering the necessary stove to heat
sensitive wall distances (See Tables below) and checking the practicability of installing the flue system
through the ceiling and roof. Heat resistant walls covered with heat sensitive surface treatments (e.g.
wallpaper or heat sensitive paints) should be regarded as heat sensitive walls. The flue shielding and
the 25mm clearance gap around it above the ceiling will occupy a diameter of 300mm (Grandview
and Toronto 325mm), and this must be available without the removal of structural beams. Flue
installations other than strictly vertical ones are possible. See current Australian and New Zealand
Standards for information on flues passing through walls and eaves.
Detailed dimensional requirements for the flue installation are included with every MASPORT
approved flue system.
NEW ZEALAND
Model
Horizon
LE 2000
Siena
LE 3000
Series 2
LE 5000
Series 2
Verona
Toronto
Panorama
Series 3
Grandview
* All flue heat shields are polished stainless steel with top Heat Dispersal Cap.
§ Valid only when the room walls are at 90° to each other.
Note: Clearances are for fire hazard only. For durability of finishes or surfaces you should contact
the relevant manufacturer for their specification. Masport accepts no responsibility for the
deterioration of surfaces or finishes.
— MINIMUM DISTANCES TO HEAT SENSITIVE WALLS (mm) ‡
Flue Heat Shield
YES - 1200 mm*
NO
YES - 1200mm*
NO
YES - 1200 mm*
NO
YES - 1200 mm*
NO
YES - 1200 mm*
YES - 900mm*
NO
YES - 1200 mm*
NO
YES - 900 mm*
NO
A
B
C
50
300 220 578
300 300 470 578 150 455 645
100 250 270 528
360 250 530 528 230 535 760
50
245 275 575
300 270 525 600 225 580 820
50
245 275 575
300 270 525 600 225 580 820
125 300 345 630 125 480 680
125 400 320 730
475 400 670 730 300 675 955
50
345 275 675
300 345 525 675 250 580 820
200 350 395 730
450 350 645 730 250 658 930
4
D
E
F
R
§
50
355 500
50
355 500
25
380 540
25
380 540
50
425 600
50
380 540
50
458 650

Hide quick links: