24.8.2 CHANGE OIL IN FINAL DRIVE CASE
• The oil is at high temperature immediately after the machine
has been operated. Wait for the oil to cool down before carry-
ing out maintenance.
• If there is still pressure remaining inside the case, the oil or
plug may fly out.
Loosen the plug slowly to release the pressure.
Prepare the following.
Container to catch drained oil: Min. 2.5 l capacity (PC130),
Refill capacity: 2.5 l (PC130),
4.0 l (PC150LGP)
Hexagon wrench
1.
Set the machine with plug
surface.
2.
Set a container under plug
3.
Remove plugs
and
4.
Tighten plug
.
5.
Add engine oil through the hole of plug
REMARK
Check the O-rings in the plugs for damage. If necessary, replace with
new ones.
6.
When the oil overflows from the hole of plug
WARNING
Min. 4.0 l capacity (PC150LGP)
and plug
perpendicular to the ground
to catch the oil.
with the hexagon wrench and drain the oil.
.
, install plug
24. SERVICE PROCEDURE
.