24. SERVICE PROCEDURE
24.3.3 CHECK FUEL LEVEL, ADD FUEL
When adding fuel, never let the fuel overflow. This may cause a
fire. If spilling fuel, thoroughly clean up any spillage.
1.
Open the pump room door on the right side of the machine and use
sight gauge
on the rear face of the fuel tank to check that the tank
is full.
2.
If the fuel level is not within the sight gauge, add fuel through filler
port
while watching sight gauge
Fuel capacity 240 liters
NOTICE
For details of the fuel to use, see "20. USE OF FUEL, COOLANT
AND LUBRICANTS ACCORDING TO AMBIENT TEMPERATURE".
3.
After adding fuel, tighten the cap securely.
REMARK
If breather hole
on the cap is clogged, the pressure in the tank will
drop and fuel will not flow. Clean the hole from time to time.
3-42
WARNING
.