SLK preparation
An unbuffered prefetch is configured that transmits both the MDT status (see
Chapter 4.3.2.1 "MDT status register") and the control data (e.g., 9 bytes as of
MDT address 0x0024) in the event-oriented data channel. The SLK switches to auto
disconnect mode and the link state switches to CONNECTING.
No.
PCP
Index
communication
1
Deactivate
0x5FF1 0x0000
unbuffered
prefetch so no
parameters are
set
2
Delete old
0x5FF1 0x0004
prefetch entries
3
Set parameters
0x5FF0
for first data
block in unbuf-
fered prefetch:
1-byte MDT
status
4
Set parameters
0x5FF0
for second data
block in unbuf-
fered prefetch:
8 bytes starting
from MDT ad-
dress 0x0024
5
Finished setting
0x5FF1 0x0001
parameters, acti-
vate unbuffered
prefetch
6
Switch SLK to
0x5FF5
auto disconnect
mode
7
Make SLK
Via process data channel:
ready to receive
(CONNECT)
Byte 0: 0x01 (switch trigger bit: now 0, used to be 1)
8
SLK operation
Wait until event counter in event-oriented data channel (see Chapter 7.3.1 "Status informa-
tion in event-oriented data channel") to increase by 1. At this point, a workpiece pallet has
arrived, the event-oriented data is valid and the link is DISCONNECTED. The MDT status and
control data can be checked and the workpiece pallet can be raised.
Subindex 0
Subindex 1
Subindex 2
0x00020000
0x0001
0x00000024
0x0009
0x00030002
0x0001
3 842 530 344/2014-05, MIT: ID 40, Bosch Rexroth AG
PROOF COPy 1 | 20.05.2014 | FOR INTERNAL USE ONLy
Interbus
81/176
Subindex 3
0x02
Write data