102/176 CANopen
Bosch Rexroth AG, MIT: ID 40, 3 842 530 344/2014-05
PROOF COPy 1 | 20.05.2014 | FOR INTERNAL USE ONLy
9.9.1.1
Object 1600-1601: Receive PDO mapping parameters
These parameters are available in the 160x objects, whereby x + 1 stands for the
number of each RPDO channel.
Table 35: RPDO mapping 1
Index
Subindex
Description
1600
00
No. mapped objects
01
PDO valid
02
Commanded link state
03
Auto mode configuration
04
SLK operative flag
05
MDT counter - high byte (byte 3)
06
MDT counter - byte 2
07
MDT counter - byte 1
08
MDT counter - low byte (byte 0)
Table 36: RPDO mapping 2
Index
Subindex
Description
1601
00
No. mapped objects
01
PDO valid
02
MDT status
03
Byte at MDT address 0x0000
04
Byte at MDT address 0x0001
05
Byte at MDT address 0x0002
06
Byte at MDT address 0x0003
07
Byte at MDT address 0x0004
08
Byte at MDT address 0x0005
9.9.1.2
Object 1A00-1A03: Transmit PDO mapping parameters
These parameters are available in the 1A0x objects.
Table 37: TPDO mapping 1
Index
Subindex
Description
1A00
00
No. mapped objects
01
PDO valid
02
Actual link state
03
Auto mode configuration
04
SLK operative flag
05
MDT counter - high byte (byte 3)
06
MDT counter - byte 2
07
MDT counter - byte 1
08
MDT counter - low byte (byte 0)
Value (index)
8
2040/01
2600/02
2600/03
2600/04
2600/05
2600/06
2600/07
2600/08
Value (index)
8
2041/01
2800/01
2200/01
2200/02
2200/03
2200/04
2200/05
2200/06
Value (index)
8
2030/01
2600/01
2600/03
2600/04
2600/05
2600/06
2600/07
2600/08