SLK preparation
The application data is read/written using the transfer buffers. The buffer mapping
has to be configured once for each buffer. Afterward, the SLK switches to the link
state CONNECTING with the command-oriented data exchange.
No.
Action
1
Lock both transfer buffers, 0 and 1, so
buffer mapping can be configured
2
Delete mappings for buffers 0 and 1
3
Prepare first mapping for transfer buffer
0 to read MDT status
4
Prepare second mapping for transfer
buffer 0 to read 32 bytes starting at
MDT address 0x0110
5
Configure both mappings for buffer 0
by entering the number of mappings in
subindex 0.
6
Prepare transfer buffer 1 mapping to
write 60 bytes starting at MDT address
0x0100
7
Configure mapping for buffer 1 by enter-
ing the number of mappings in subindex
0, in this case 1
8
Activate transfer buffer 1 for direct data
exchange
9
Activate transfer buffer 0 as prefetch
buffer. The mapped data blocks will be
read automatically from the next MDT
10
Make SLK ready to receive
(CONNECTING)
COB
rd/wr
SDO
wr
SDO
wr
SDO
wr
SDO
wr
SDO
wr
SDO
wr
SDO
wr
SDO
wr
SDO
wr
SDO
wr
SDO
wr
SDO
wr
3 842 530 344/2014-05, MIT: ID 40, Bosch Rexroth AG
PROOF COPy 1 | 20.05.2014 | FOR INTERNAL USE ONLy
CANopen 111/176
Index/
Data
subindex
2100/01
0x00
2101/01
0x00
2110/00
0x00000000
2111/00
0x00000000
2110/01
0x80000001
2110/02
0x00440020
2110/00
0x00000002
2111/02
0x0040003C
2111/00
0x00000001
2101/01
0x01
2100/01
0x03
2600/02
0x01