Optional Framing Kit - Regency Fireplace Products City CB60EPV-NG Owners & Installation Manual

Direct vent gas power vent fireplace
Table of Contents

Advertisement

Optional Framing Kit

Optional Framing Kit
Tools/hardware required:
- Level
- Stud finder
- Cordless screwdriver
- Phillips bit
- 5/16 inch hex head bit
- 2'' to 3'' wood screws (minimum 16)
- Flashlight
Note: Extra screws are provided to assemble this kit.
*See last page of these instructions for assembled overview.
Before starting the installation, ensure the wall framing contains 2 additional
studs spaced 69-3/4" (1772 mm) apart from center to center. The framing will
need to be secured to these studs as well as secured to the original studs
of the wall framing.
Additional wall studs required
69-3/4" center to center
78
"
1/
2
71
"
5/16
Framing Kit with unit - Overall dimensions
920-170
tooltip
CB60E framing kit parts layout*
69 "
3/4
20 "
3/8
Note: Unit nailing strips are not required (and can be recycled) when using
the framing kit.
B
H
B
1. Assemble the back frame as shown above by assembling 2x Part B with 2x
Part H with 8 screws installed from back of frame.
Install back frame on unit
2. Install the frame assembled in Step 1, onto the back of the unit as shown
above with 2 screws on each side.
3. Place unit against wall in desired location. Level the unit by adjusting 4
leveling bolts on unit.
4. Install venting before proceeding further with framing kit construction. Refer
to manual for venting instructions.
1
installation
CITY SERIES
H
Assemble back frame
(view from back)
11.15.19