Xilinx Alveo U200 Getting Started Manual page 18

Data center accelerator cards
Hide thumbs Also See for Alveo U200:
Table of Contents

Advertisement

Figure 9:
6. If you previously removed the computer casing, re-install the casing.
7. Connect the power cord and turn on the computer.
:
Note
Do not power-on a passively cooled card without adequate forced airflow across the card, otherwise
the card can be damaged. For more information, see Alveo U200 and U250 Data Center Accelerator Cards
Data Sheet (DS962) and Alveo U280 Data Center Accelerator Cards Data Sheet (DS963).
To verify that the device has been installed correctly, enter the following Linux command in a
terminal:
$ sudo lspci -vd 10ee:
If the card is successfully installed and found by the operating system, a message similar to the
one below displays.
If you do not see a similar message, see
UG1301 (v1.3) February 12, 2019
Getting Started with Alveo Accelerator Cards
6-Pin PCIe Aux Power Connector Pin Relative to 8-Pin
Figure 8:
Example of 6-Pin to 8-Pin PCIe Aux Power Connector Cord
Chapter 7:
Chapter 3: Card Installation Procedures
Troubleshooting.
Send Feedback
www.xilinx.com
18