Fan Headers
There are six fan headers on the StorTrends 1100 motherboard, which are designated
CPU/ Chassis Fan1, Chassis Fan2, Chassis Fan3, Chassis Fan4 and OH
(Overheat)/Chassis Fan5. (Chassis Fan 3 and Chassis Fan 4 are not monitored by BIOS.)
Connect the fan on your CPU heatsink to the CPU/Chassis Fan1 header. See the table
below for pin definitions.
Fan Header Pin Definitions (CPU/ Chassis and Overheat)
Pin
1
2
3
Chassis Intrusion
The Chassis Intrusion header is designated JL1. See the board layout in Chapter 1 for the
location of JL1 and the table below for pin definitions.
Chassis Intrusion Pin Definition (JL1)
Pin
1
2
Wake-On-LAN
The Wake-On-LAN header is designated WOL on the motherboard. See the table below
for pin definitions. You must enable the LAN Wake-Up setting in BIOS to use this
function. (You must also have a LAN card with a Wake-On- LAN connector and cable to
use this feature.)
Wake-On-LAN Pin Definitions (WOL)
Pin
1
2
3
Definition
Ground (black)
+12V (red)
Tachometer
Definition
Intrusion Input
Ground
Definition
+5V Standby
Ground
Wake-Up
Chapter Five : Advanced Motherboard Setup
35