Environmental Factors And Requirements; Temperature And Humidity Conditions; Temperature Gradient - Canon imagePRESS C6000 Customer Expectation Document

Hide thumbs Also See for imagePRESS C6000:
Table of Contents

Advertisement

5.

Environmental Factors and Requirements

Operating Temperature:
Operating Humidity:
Atmospheric Pressure:
Noise (sound level):
Ozone Emissions:
NOTE
It may be necessary to use a humidifier or dehumidifier to attain the proper
humidity levels for optimal machine performance.

5.1 Temperature and Humidity Conditions

During operation, the permissible humidity range is 30% to 70% RH (Relative
Humidity) with a room temperature of 68°F to 80.6°F (20°C to 27°C).
There is a risk that paper feeding and image quality may be affected if the machine
is used in a location that does not meet these specifications.
The machine should not be installed in locations with significant shifts in
temperature or humidity. Areas containing water, or equipment, such as a heater,
stove, or portable air conditioner should be avoided unless proper environmental
control is available.
The permissible humidity range for storing paper is 30% to 70% RH (Relative
Humidity) with a room temperature of 68°F to 80.6°F (20°C to 27°C). Storing paper
in a location that does not meet these specifications may affect paper feeding and
image quality. For example, if the humidity is too high, paper curling and paper
jams will increase. If the humidity is too low, paper may shrink, lose resistance, and
toner will not adhere to the paper as well.

5.2 Temperature Gradient

Using an air conditioner during the winter, or if a sudden temperature change
occurs, may have an adverse affect on image positioning. Sudden temperature
changes may cause the paper to bend or contract, and cause a machine
malfunction due to condensation. To avoid these issues, control the temperature
gradient so that it does not exceed 18°F/H (10°C/H).
Version 5
Between 68°F (20°C) and 80.6°F (27°C)
Between 30% and 70%
810.6 to 1,013 hPa (0.8 to 1.0 atm)
Standby: 74 dB; Copying: 82 dB
0.01 ppm (parts per million) or less (initial startup)
0.035 ppm or less (after a short break-in period)