The following illustration shows the relative position of the power outlets, voltage
requirements, and dimensions of each optional accessory item.
IMPORTANT
• Canon USA strongly recommends that dedicated and properly grounded outlets
be provided for the devices mentioned above. The ground connection serves to
provide the internal electronics with a reference voltage. Faulty or poor ground
sources will cause this reference voltage to fall into a range that no longer serves
as a reliable reference voltage. The internal logic and programming of the
imagePRESS C6000 will not perform reliably because there is an insufficient
difference between the internal operating signal voltages and the poor ground
reference signal. A qualified electrician can measure and provide the ground
source that the imagePRESS C6000 or any computer controlled office equipment
requires.
• Before installation, confirm that a dedicated NEMA L14-30 receptacle is available
as needed.
Version 5
imagePRESS C6000 Customer Expectations Document
(Note: Phase converters and step down
transformers are not supported.)