5.

Environmental Factors and Requirements

This section describes the necessary environmental factors and requirements in
which the machine should be operated to achieve the best image quality and print
results.

5.1 Temperature and Humidity Conditions

The optimal humidity range is 30% to 70% RH (Relative Humidity) with a room
temperature of 68°F to 80.6°F (20°C to 27°C). Make sure to maintain a constant
temperature and humidity within this range. Otherwise, there is a risk that
productivity, paper feeding, image quality, and reliability may be affected if the
machine is operated outside of these guidelines.
The machine should not be installed in locations with significant shifts in
temperature or humidity. Areas containing water, or equipment that can
significantly alter room temperature or humidity, such as a space heater, stove, or
portable air conditioner, should be avoided.
The optimal humidity range for storing paper is 30% to 70% RH (Relative Humidity)
with a room temperature of 68°F to 80.6°F (20°C to 27°C). Storing paper in a
location that does not meet these specifications may affect paper feeding and
image quality. For example, if the humidity is too high, paper curling and paper
jams will increase. If the humidity is too low, paper may shrink or lose resistance,
and toner will not adhere to the paper as well.
Only use paper that has fully acclimatized to the environment in which the machine
is installed. Using paper that has been stored in a different environment (with a
different temperature and humidity), may cause paper jams or result in poor print
quality.

5.2 Temperature Gradient

Using an air conditioner during the winter, or if a sudden temperature change
occurs, may have an adverse affect on image positioning. Sudden temperature
changes may cause the paper to bend or contract, cause the machine to
malfunction, and form condensation. Every effort should be made to maintain
consistent temperature and humidity levels in the operating environment at all
times for the imagePRESS C6010.