Page 1
Remote control AMK P - AMS P - AMC P USER INSTRUCTIONS...
Page 2
Thank you for choosing a R product, an innovative and high quality appliance that guarantees wellbeing for a long time. This manual contains information we deem necessary for correct and easy use. Thanks again. RIELLO COMPLIANCE R AMK P - AMS P - AMC P heat pumps are compliant with the following European Directives: —...
GENErAl iNforMAtioN GENERAL INFORMATION This unit contains fluorinated greenhouse gases covered General Notices by the Kyoto protocol. Maintenance and disposal activities must be carried out exclusively by skilled personnel. R32 refrigerant gas is slightly flammable and odourless. When you get the product, check immediately that the con- tents are all present and undamaged.
GENErAl iNforMAtioN Keep the air filter clean. Clogged air filters are a cause of inefficient operation and waste of energy. AMK P 1.4.1 Unit description R AMK P is an indoor unit for ceiling installation, suitable for unit. The multiple-speed fan DC motor improves performance use in commercial premises in combination with the outdoor and sound comfort.
GENErAl iNforMAtioN Unit display The unit display shows the active functioning mode, the tem- perature and the alarms, if any. Temperature indication, alarm code Display AMS P 1.5.1 Unit description R AMS P is an indoor unit for ceiling or floor installation, combination with the outdoor unit.
GENErAl iNforMAtioN 1.5.4 Layout Electrical box Air intake grille Refrigerant connections Display Heat exchanger Motorised deflector Front panel Remote control Unit display The unit display shows the active functioning mode, the tem- perature and the alarms, if any. Wi-Fi on Remote control receiver Temperature indication, alarm code Display...
GENErAl iNforMAtioN 1.6.3 Identification The unit can be identified through the technical data plate: technical data plate Contains the device's technical and performance data. The tampering, removal, or absence of the identification plates will not allow the product to be properly identified by its serial number.
GENErAl iNforMAtioN Remote control Control, setting and programming operations are carried out Function not available with the IR remote control. The electronics modulates the device operation according to the temperatures detected by the probes inside the indoor and out- door units. Door oPEN function keys The remote control features a small door in the key area:...
GENErAl iNforMAtioN timer settings Delete the settings Switch on or off the unit display Timer setting value or current time display Indoor unit processing Press to restart the air conditioner Switch on timer enabled Switch off timer enabled Private function Keys locking functions remote control display...
Initial settings The remote control was designed to ensure user-friendliness even with no special programming. To activate, just install batteries and set current time. Battery insertion The remote control is powered by two AAA batteries (1.5 V) housed at the back, under a cover. Should you notice a poorer reception or if display information fades out, the batteries must be changed.
The compressor activates 3 minutes after unit activation. — work on Use with closed flap Value is stored with no need to press other buttons. • Switch-off — select another operating mode Door CloSED Alternatively: — press to deactivate Heating Mode The Heating mode allows starting and use of the air conditioner as a hot air producer.
Set required ventilation speed as follows: • Activation — press appears on the display of the remote control and the unit. Set required temperature as follows: Minimum speed Medium speed — work on Maximum speed Value is stored with no need to press other buttons. Automatic speed •...
— Heating — Cooling • Activation — press • Switch-off — select another operating mode Initial position Alternatively: — press to deactivate — work on — select required position Maximum power function Each press will select a different position. Once the desired deflector is selected, adjust the air flow through Equipment operation is forced to maximum so as to quickly the horizontal air deflector.
— select required position Each press will select a different position. In environments with high humidity, condensation may form on the deflector during operation in Cooling and Dehumidification mode. In this situation, if the deflector is kept in vertical position for a long time, condensation may fall on the objects below.
Automatic switch-on The display shows the and the time previously set. Set required time as follows: Automatic switch-on programming allows user to set equip- ment ON time. — work on before activation, set current time. — Each time the key is pressed, the values changes by 1. by keeping the key pressed down, the value changes faster.
• Stop for an extended period of time button locking — press If the device has not been used for an extended period of time, Remote control display shows carry out the following operations: • button unlocking — start the device in ventilation mode —...
Stubborn dirt can be removed by washing the filter in a luke Exposing the filters to the sun or washing them with water warm (max. 40 °C) solution of water and neutral detergent. at a temperature that is higher than 40 °C can cause the After washing, rinse the filters well and leave to dry in the filters to shrink.
Page 19
Stubborn dirt can be removed by washing the filter in a luke Exposing the filters to the sun or washing them with water warm (max. 40 °C) solution of water and neutral detergent. at a temperature that is higher than 40 °C can cause the After washing, rinse the filters well and leave to dry in the filters to shrink.
Page 20
indoor unit faults LED1 Display Description Remarks Room probe fault Exchanger probe fault Microprocessor malfunction Communication error between indoor unit and outdoor unit The unit resets after problem Communication error between resolution unit and control panel Malfunction condensation drain system Zero cross signal detected wrong Fan motor malfunction...
Page 21
indoor unit faults outdoor unit faults LED1 Display Description Remarks Refer to the matching outdoor unit instruction booklet for Room probe fault the installer. Exchanger probe fault Microprocessor malfunction Communication error between indoor unit and outdoor unit The unit resets after problem Communication error between resolution unit and control panel...
Page 22
rECyCliNG AND DiSPoSAl DiSPoSAl Packing materials must be disposed of separately, in order to be recovered and recycled. Equipment at end of life and flat bat- teries must be disposed of as required by prevailing law and regulations.
Page 24