General Information
General Notices
General information and warnings about product receipt and installation.
Safety Precautions
Essential safety regulations for using electrical products.
Unit Description
Details the indoor unit for wall installation and its fan motor.
Safety and Adjustment Devices
Explains sensors and devices ensuring unit safety and setting.
Identification
How to identify the unit using its technical data plate.
Layout
Illustrates the physical components and layout of the indoor unit.
Technical Specifications
Provides detailed performance data, sound levels, and electrical characteristics.
Cooling Circuit
Diagram and explanation of the indoor unit's cooling circuit components.
Installation
Receiving the Product
Lists items found inside the packaging upon delivery.
Dimensions and Weight
Provides packaging dimensions and weight for different models.
Storage
Regulations and advice for storing the product before installation.
Handling and Packing Removal
Instructions for safely unpacking and handling the unit.
Place of Installation
Guidelines for selecting the optimal indoor unit installation location.
Recommended Distances
Specifies clearances required for installation and maintenance.
Installation on Old Systems
Recommendations for installing on existing or upgraded systems.
Positioning
Instructions on how to position and fix the unit to the wall using the support.
Fixing the Metallic Support
Step-by-step guide for attaching the wall support bracket.
Drilling into the Wall
Instructions for drilling holes through the wall for connections.
Device Preparation
Steps to prepare the unit before making connections, like removing inserts.
Assembly
Steps for assembling the unit onto the metallic support.
Condensate Discharge Position
How to position the condensate discharge hole and pipe.
Refrigerating Connection
Details dimensions and positions for refrigerant pipe connections.
Connection Specifications by Model
Details pipe sizes and connection outlets for various AMW ST models.
Wall Penetration and Pipe Protection
Instructions for drilling wall holes and protecting pipes.
Pipe Flaring and Connection Tightening
Step-by-step guide for flaring pipes and tightening connections with torque values.
Pipe Insulation
Requirements for insulating refrigerant pipes to prevent heat loss and condensate.
Condensate Discharge Connection
How to connect the condensate drain pipe and requirements for a syphon.
Drainage Check
Procedure to check the condensate drainage system's functionality.
Wiring Diagram
Electrical wiring diagram for model 25-35.
Electrical Connection
Steps to access the terminal board and connect the unit to the outdoor unit.
Electric Connections
Guidelines for making electrical connections, cable sizing, and earthing.
Remote Control
Introduction to the remote control and battery insertion.
Remote Control Functions (Door Closed)
Explains quick function keys available when the remote control door is closed.
Remote Control Functions (Door Open)
Explains advanced function keys available when the remote control door is open.
Remote Control Display Details
Describes the icons and indicators on the remote control display.
Unit Display
Explains the indicators on the indoor unit's display.
Light Indicators
Explains the meaning of the indicator lights on the indoor unit.
Commissioning and Maintenance
Preparation for First Commissioning
Checks required before initial operation of the unit.
Microswitch Setting
Describes the function and factory settings of internal microswitches.
Purifying Filter Installation
Instructions for installing antibacterial and photocatalytic air purifying filters.
Time Setting
Procedure to set the current time on the remote control.
Putting into Service
Steps to activate and check the unit's operation after first commissioning.
Checks During and After First Commissioning
Verification steps and potential issues after initial startup.
Temporary Shutdown
How to temporarily disable the unit using the remote control.
Stop for Extended Period
Recommended procedure for long-term storage of the unit.
Ordinary Maintenance
Importance and conditions for performing periodic maintenance.
Monthly Operations
List of checks to be performed on a monthly basis.
Mesh Filter Cleaning
Steps for cleaning the mesh filters of the indoor unit.
Yearly Operations
List of checks to be performed annually.
Purifying Filter Replacement
Instructions on how to replace the air purifying filters.
Extraordinary Maintenance
Procedure for removing the unit for repair or replacement.
Alarms
Explains that the unit is blocked during operating abnormalities and safety blocks.
Outdoor Unit Faults
Table detailing fault codes, indications, and remarks for outdoor unit issues.
Disposal
Packaging and End-of-Life Disposal
Guidance on disposing of packaging and the device at its end of service life.