Table 4.
Model
063/E006
125/E013
250/E025
500/E051
1000/E091
2000/E171
NOTE
1. A = absorbed current (Amp) at nominal conditions (output torque 100%)
2. Max current (Amp) at stall conditions = 1.2 x A
3. Power factor for V AC supply = 0.60
4. Peak current: max 8xIn
5. Peak current duration: less than 0.1 s
20
Current Absorption - Three-Phase Voltage
Operating
Selected
Time
Step
(s/90°)
208 V AC
8
15
0.226
6
28
0.165
4
48
0.132
8
15
0.344
6
28
0.295
4
48
0.245
8
15
0.800
6
28
0.590
4
48
0.530
8
15
1.073
6
28
0.720
4
48
0.590
8
24
1.073
6
45
0.720
4
80
0.590
8
53
1.073
6
100
0.720
4
180
0.590
Installation and Maintenance Instructions
Current Absorption (A)
240 V AC
380 V AC
400 V AC
0.176
0.101
0.083
0.227
0.180
0.155
0.73
0.52
0.56
0.41
0.50
0.37
0.97
0.65
0.64
0.47
0.55
0.41
0.97
0.65
0.64
0.47
0.55
0.41
0.97
0.65
0.64
0.47
0.55
0.41
MAN-02-04-99-0712-EN Rev. 1
480 V AC
500 V AC
575 V AC
0.107
0.080
0.057
0.171
0.143
0.125
0.49
0.37
0.340
0.35
0.29
0.280
0.30
0.27
0.250
0.58
0.46
0.430
0.39
0.32
0.310
0.32
0.29
0.280
0.58
0.46
0.430
0.39
0.32
0.310
0.32
0.29
0.280
0.58
0.46
0.430
0.39
0.32
0.310
0.32
0.29
0.280
Installation