8.1 Programming the master combination

Possible only with the electronic lock open and only by using the master combination.
Function
Initiate programming
Select P - No. 0
Confirm the entry
Enter previous 6-digit combination, e.g. °
Confirm the entry
Enter new 6-digit combination, e.g.
Confirm the entry
Enter new combination again to confirm
Confirm the entry
Cancel

8.1.1 Programming a new primary combination using the emergency opening lock

Possible only with the electronic lock closed and the emergency opening lock released.
Function
Initiate programming
Select P - No. 0
Confirm the entry
Enter new 6-digit combination, e.g.
Confirm the entry
Enter new combination again to confirm
Confirm the entry
Cancel
If a new combination is not entered after opening the emergency release lock the previous combination will be retained after
the lock is closed.

8.2 Programming a user combination

A user combination can be set up for the first time only by the master combination owner.
Changes to a user combination may be made with either the master combination or the particular user
combination. Programming is possible only with the electronic lock open.
Function
Initiate programming
Select P - No. 1
Confirm the entry
Select user number e.g. 1 °
Confirm the entry
Enter the 6-digit master
or user combination, e.g.
Confirm the entry
Enter the new 6-digit
user combination, e.g.
Confirm the entry
Enter the new 6-digit user combination
again to confirm
Confirm the entry
Cancel
B7202_E_1.pmd
Operation, button(s)
Response
Green LED blinks once
OK = green LED blinks once
and low-high tone sounds.
Error = 12 high-pitched
tones and red LED lights.
Operation, button(s)
Response
Green LED blinks once
OK = green LED blinks once
and low-high tone sounds.
Error = 12 high-pitched
tones and red LED lights.
Operation, button(s)
Response
Green LED blinks once
4
5
6
7
8
9
4
5
6
7
8
9
OK = green LED blinks once
and low-high tone sounds.
Error = 12 high-pitched
tones and red LED lights.
12.06.2003
Bedienungsanleitung Nr. 9999-041-0
Comments
° Set at the factory for
1 - 2 - 3 - 4 - 5 - 6
Please check to
ensure that the lock
functions correctly
with the new master
combination before
closing the safe door.
Comments
° Set at the factory for
1 - 2 - 3 - 4 - 5 - 6
Please check to
ensure that the lock
functions correctly
with the new master
combination before
closing the safe door.
Comments
A maximum of 5 user
combinations can be
programmed
°
= UNo. 1
= UNo. 5
The previous user
combination will be
retained if there is
an error in
programming.