Technical data
11.1 Rated conditions
Table 11-10
Type 2N
Head type
T
max
Max. permitted power con‐
sumption of electronic (W)
Medium
Tempera‐
temperature
ture in‐
(°C)
crease by
Medi‐
um ΔT2D
(K)
100 °C
10
80 °C
8
Assembled temperature transmitter for example SITRANS TH
1)
11.1.3

Maximum permitted sample temperatures within the process

Note
Permissible ambient temperature at sensor
The maximum permissible ambient temperature at the sensor simultaneously corresponds to
the highest permissible sample temperature.
The minimum permissible sample temperatures are up to -200 °C depending on the version of
the temperature sensor.
See also
Maximum permitted sample temperatures within the process (Page 138)
Resistance thermometers
Table 11-11
RTD temperature sensor (R
1 x RTD TF/3 mm/6 mm
2 x RTD TF/3 mm/6 mm
1 x RTD WW/3 mm/6 mm
2 x RTD WW/3 mm/6 mm
T1 = 450 °C -10K
T2 = 300 °C -10K
T3 = 200 °C - 5K
138
AH0, AV0, SITRANS TF
head
T85 °C
0
Without
With elec‐
electronic
T
in °C
T
a_max
a_max
75
53
85
63
max=120 K/W)
th
Max. permissible sample temperature (°C)
Certified transmitter in Zone 0 with type of
protection "Intrinsically safe"
P0: 0 ... ≤37 mW
1)
348
228
152
AG0, UG0
100 °C
1
0
1)
Without
tronic
electronic
in °C
T
in °C
a_max
100
100
P0: ≥37 ... ≤100 mW
340
220
144
SITRANS TS100/TS200/TS300/TS500/TSinsert/TSthermowell
AU0, UU0
1
0
1)
With elec‐
Without
tronic
electronic
T
in °C
T
in °C
a_max
a_max
53
120
63
120
Certified transmitter in Zone 1, 2 with
type
of protection "Intrinsically safe"
P0: 0 ... ≤37 mW
P0: ≥37 ... ≤100
1)
mW
436
286
191
Operating Instructions, 08/2020, A5E47810090-AA
120 °C
1
1)
With elec‐
tronic
T
in °C
a_max
53
63
428
278
183