SITRANS
Temperaturmessumformer
SITRANS TH320/TH420/TR320/
TR420/TF320/TF420
Compact Operating Instructions
03/2018
A5E41865021-AA
Introduction
Safety notes
Installing/mounting
Connecting
Commissioning
Service and maintenance
Technical specifications
Appendix A
1
2
3
4
5
6
7
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SITRANS Series

  • Page 1 Introduction Safety notes Installing/mounting SITRANS Connecting Temperaturmessumformer SITRANS TH320/TH420/TR320/ Commissioning TR420/TF320/TF420 Service and maintenance Compact Operating Instructions Technical specifications Appendix A 03/2018 A5E41865021-AA...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Introduction..............................7 Purpose of this documentation....................7 Document history........................7 Scope of validity of this document....................7 Product compatibility........................8 Intended use..........................8 Nameplate layout........................10 1.6.1 Nameplate layout SITRANS TH.....................10 1.6.2 Nameplate layout SITRANS TR.....................11 1.6.3 Nameplate layout SITRANS TF.....................12 Checking the consignment.....................12 Security information.......................13 Transportation and storage....................13 1.10...
  • Page 4 Table of contents 3.6.1 Mounting device to a pole with mounting bracket..............26 3.6.2 Mounting device to the wall with mounting bracket..............27 Disassembly...........................29 Connecting..............................31 Basic safety notes........................31 4.1.1 Connecting device in energized state in hazardous areas.............32 Connecting TH320.........................33 Connecting TH420.........................34 Connecting TR320.........................35 Connecting TR420.........................37 Connecting the SITRANS TF dual chamber housing.............39 4.6.1...
  • Page 5 Table of contents Construction...........................65 Common specifications......................66 Certificates and approvals......................67 7.4.1 ATEX/IECEx and related......................67 7.4.2 FM/CSA..........................72 Display...........................75 Appendix A..............................77 Technical support........................77 Certificates..........................77 Index................................79 SITRANS TH320/TH420/TR320/TR420/TF320/TF420 Compact Operating Instructions, 03/2018, A5E41865021-AA...
  • Page 6 Table of contents SITRANS TH320/TH420/TR320/TR420/TF320/TF420 Compact Operating Instructions, 03/2018, A5E41865021-AA...
  • Page 7: Introduction

    Introduction Purpose of this documentation These instructions are a brief summary of important features, functions and safety information, and contain all information required for safe use of the device. Read the instructions carefully prior to installation and commissioning. In order to use the device correctly, first review its principle of operation.
  • Page 8: Product Compatibility

    Introduction 1.5 Intended use Product compatibility The following table describes the compatibility between the edition of this manual, the device revision, the engineering system and the associated EDD. Manual Comments Device revision Compatible version of device integration package edition 03/2018 First edition HART 7 SIMATIC PDM V9.1...
  • Page 9 Introduction 1.5 Intended use The output signal is a load-independent direct current from 4 to 20 mA in accordance with the input characteristic, superimposed by the digital HART signal. The dual input mode also supports drift detection of the inputs, whereby maintenance intervals can be more easily planned.
  • Page 10: Nameplate Layout

    Introduction 1.6 Nameplate layout Nameplate layout 1.6.1 Nameplate layout SITRANS TH ① Conformity with country-specific guidelines ② Manufacturer's address ③ Place of manufacture ④ Read the compact operating instructions ⑤ CE marking with ID number of the named testing authority ⑥...
  • Page 11: Nameplate Layout Sitrans Tr

    Introduction 1.6 Nameplate layout 1.6.2 Nameplate layout SITRANS TR ① ⑦ Manufacturer CE marking with ID number of the named testing authority ② ⑧ QR code for mobile website with device-spe‐ Device version cific information about the product ③ ⑨ Conformity with country-specific guidelines Serial number ④...
  • Page 12: Nameplate Layout Sitrans Tf

    Nameplate layout SITRANS TF TEMPERATURE TRANSMITTER (S) N1J7002729 SITRANS TF320 HART SIL (1P) 7NG0320-0BA00-0AA0-Z DEVICE NO: nn.nn.nn. Siemens AG C11+C20+D10+D81+D90+P10+V01+W02+Y04 DE-76181 Karlsruhe Made in France UB: DC 13.1...32V; lo: 4...20mA+HART IP66/68 II 1 G Ex ia II C T6/ T5/T4 Ga or...
  • Page 13: Security Information

    Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber...
  • Page 14: Notes On Warranty

    The content reflects the technical status at the time of publishing. Siemens reserves the right to make technical changes in the course of further development.
  • Page 15: Safety Notes

    Safety notes Prerequisites for safe use This device left the factory in good working condition. In order to maintain this status and to ensure safe operation of the device, observe these instructions and all the specifications relevant to safety. Observe the information and symbols on the device. Do not remove any information or symbols from the device.
  • Page 16: Requirements For Special Applications

    If you need additional information not covered by these instructions, contact your local Siemens office or company representative. Note Operation under special ambient conditions...
  • Page 17 Safety notes 2.3 Use in hazardous areas WARNING Use in hazardous area Risk of explosion. ● Only use equipment that is approved for use in the intended hazardous area and labelled accordingly. ● Don't use devices that have been operated outside the conditions secified for hazardous areas.
  • Page 18 Safety notes 2.3 Use in hazardous areas SITRANS TH320/TH420/TR320/TR420/TF320/TF420 Compact Operating Instructions, 03/2018, A5E41865021-AA...
  • Page 19: Installing/Mounting

    Installing/mounting Basic safety notes 3.1.1 ATEX/IECEx and others 3.1.1.1 Safety information for installation in "Intrinsic safety "ia/ib" Zones 0, 1, 2, 20, 21, 22 and M1 General installation information The first two digits of the serial number stand for the year of production. With aluminum enclosures, you also have to make sure during installation that ignition sources due to sparks caused by impact or friction are prevented.
  • Page 20: Safety Information For Installation In "Non-Sparking Na/Ec" And "Intrinsic Safety Ic

    Installing/mounting 3.1 Basic safety notes Aluminum enclosure are not permitted in mines. The enclosure must be suitable for the application and installed to meet the applicable regulations. Cable entries and dummy elements must meet the same requirements. 3.1.1.2 Safety information for installation in "Non-sparking nA/ec" and "Intrinsic safety ic" Zone 2 and 22 General installation instructions If the enclosure is made of non-metallic materials or of painted metal, electrostatic charging...
  • Page 21: Csa/Fm

    Installing/mounting 3.1 Basic safety notes 3.1.2 CSA/FM 3.1.2.1 Safety information for installation in "Intrinsic safety "ia" Hazardous Area CL I, Div 1, GP ABCD CL I, Zone 0 IIC General installation instructions ● Install in accordance with the US the National Electrical Code (NEC) or for Canada the Canadian Electrical Code (CEC).
  • Page 22: Safety Information For Installation In "Non Incendive Na

    Installing/mounting 3.1 Basic safety notes 3.1.2.2 Safety information for installation in "Non Incendive nA" Hazardous Area CL I, Div 2, GP ABCD CL I, Zone 2 IIC General installation instructions ● The transmitter must be installed in an enclosure providing a degree of protection of at least IP54 according to IEC 60529 that is suitable for the application and is correctly installed.Cable entry devices and blanking elements shall fulfill the same requirements.
  • Page 23: Installing Sitrans Th In A Connection Head

    Installing/mounting 3.2 Installing SITRANS TH in a connection head NOTICE Use of line and cable entries made of plastic in hazardous areas Device damage caused by impact at temperatures below -20 °C. ● Make sure that the line and cable entries are protected from impacts. Installing SITRANS TH in a connection head Note The transmitter is only designed for installation in a type B connection head or larger.
  • Page 24: Installing Sitrans Th On Din Rail And G Rail

    Installing/mounting 3.3 Installing SITRANS TH on DIN rail and G rail Note Using the lock washers (SITRANS TH) ④ The lock washers included in the delivery are only required for securely fastening the ② ③ transmitter when the transmitter is directly installed on the round plate of a temperature probe.
  • Page 25: Installing Sitrans Tr On Din Rail

    Installing/mounting 3.5 Mounting the SITRANS TF single chamber housing Figure 3-1 Securing the transmitter on DIN rails Figure 3-2 Securing the transmitter on G rails Installing SITRANS TR on DIN rail The transmitter is secured to a 35 mm DIN rail in accordance with DIN EN 60715. Comply with the ambient conditions specified in the technical data.
  • Page 26: Mounting The Sitrans Tf Dual Chamber Housing

    Installing/mounting 3.6 Mounting the SITRANS TF dual chamber housing Procedure ① Mounting holes for mounting to a pipe clamp or wall ② Mounting holes for fastening mounting plate on device Figure 3-3 Mounting device to a pipe clamp or wall with rail 1.
  • Page 27: Mounting Device To The Wall With Mounting Bracket

    Installing/mounting 3.6 Mounting the SITRANS TF dual chamber housing Procedure ① ⑤ Mounting holes on the enclosure Nut M8 ② ⑥ Mounting holes in the mounting bracket (90° ro‐ Washer DIN 125 - 8.4 tatable) ③ ⑦ Washer DIN 125 - 8.4 Pole clamp for mounting to pole ④...
  • Page 28 Installing/mounting 3.6 Mounting the SITRANS TF dual chamber housing Procedure ① ④ Mounting holes on the enclosure Fixing screws M8 or 5/16 UNF thread ② ⑤ Mounting holes in the mounting bracket Fixing screws (90° rotatable) ③ Washer DIN 125 - 8.4 Figure 3-5 Mounting device to the wall with mounting bracket ①...
  • Page 29: Disassembly

    Installing/mounting 3.7 Disassembly Disassembly WARNING Incorrect disassembly The following risks may result from incorrect disassembly: - Injury through electric shock - Risk through emerging media when connected to the process - Risk of explosion in hazardous area In order to disassemble correctly, observe the following: ●...
  • Page 30 Installing/mounting 3.7 Disassembly SITRANS TH320/TH420/TR320/TR420/TF320/TF420 Compact Operating Instructions, 03/2018, A5E41865021-AA...
  • Page 31: Connecting

    Connecting Basic safety notes WARNING Unsuitable cables, cable glands and/or plugs Risk of explosion in hazardous areas. ● Use only cable glands/plugs that comply with the requirements for the relevant type of protection. ● Tighten the cable glands in accordance with the torques specified in Technical specifications (Page 65).
  • Page 32: Connecting Device In Energized State In Hazardous Areas

    Connecting 4.1 Basic safety notes 4.1.1 Connecting device in energized state in hazardous areas WARNING Connecting device in energized state Risk of explosion in hazardous areas. ● Connect devices in hazardous areas only in a de-energized state. Exceptions: ● Devices having the type of protection "Intrinsic safety Ex i" may also be connected in energized state in hazardous areas.
  • Page 33: Connecting Th320

    Connecting 4.2 Connecting TH320 Connecting TH320 Procedure 1. Connect the input or inputs to terminals 3 to 6. 2-wire, 3-wire or 4-wire RTD or TC (internal CJC or linear resistance external 2-wire or 3-wire CJC) I1: Input 1 Voltage input 3-wire or 4-wire potentiometer (single-pole or two-pole) 2.
  • Page 34: Connecting Th420

    Connecting 4.3 Connecting TH420 Connecting TH420 Procedure 1. Connect the input or inputs to terminals 3 to 9. Input 1 (I1) and/or Input 1 (I1) and/or Input 1 (I1) and/or input 2 (I2): input 2 (I2): input 2 (I2): 2-wire, 3-wire or 4-wire RTD or TC (int.
  • Page 35: Connecting Tr320

    Connecting 4.4 Connecting TR320 Connecting TR320 Procedure 1. Connect the input or inputs to terminals 5 to 8. The terminals are equipped with a coding profile to ensure intrinsic safety. 2-wire, 3-wire or 4-wire RTD or TC (internal CJC or wire resistance external 2-wire or 3-wire CJC) I1: Input 1...
  • Page 36 Connecting 4.4 Connecting TR320 For devices with HART communication, connect a ≥ 250 Ω resistor. 3. Take the polarity into account. The device has reverse polarity protection. SITRANS TH320/TH420/TR320/TR420/TF320/TF420 Compact Operating Instructions, 03/2018, A5E41865021-AA...
  • Page 37: Connecting Tr420

    Connecting 4.5 Connecting TR420 Connecting TR420 Procedure 1. Connect the input or inputs to terminals 5 to 12. The terminals are equipped with a coding profile to ensure intrinsic safety. Input 1 (I1) and/or input 2 (I2): Input 1 and/or input 2: Voltage input 2-wire, 3-wire or 4-wire RTD or TC (int.
  • Page 38 Connecting 4.5 Connecting TR420 Input 1: TC (int. CJC or Input 1 (I1) and/or Input 1 (I1): 5-wire potentiome‐ ext. 2-wire or 3-wire CJC) input 2 (I2): Input 2: 2-wire, 3-wire or 4-wire 3-wire or 4-wire potentiometer Input 2 (I2): 3-wire potentiome‐ 2.
  • Page 39: Connecting The Sitrans Tf Dual Chamber Housing

    Connecting 4.6 Connecting the SITRANS TF dual chamber housing Connecting the SITRANS TF dual chamber housing 4.6.1 Opening the device Procedure ⑥ Cover of the electrical cable compartment ⑦ Safety catch (back) Figure 4-1 Rear view of the device ⑦ 1.
  • Page 40: Connecting The Sitrans Tf320 Dual Chamber Housing

    Connecting 4.6 Connecting the SITRANS TF dual chamber housing 4.6.2 Connecting the SITRANS TF320 dual chamber housing Procedure ① ⑤ Supply voltage Input terminals ② ⑥ HART communication resistor (optional) Protective conductor connector ③ ⑦ Cable gland Ground terminal ④ Test terminals Figure 4-2 Connecting the device...
  • Page 41 Connecting 4.6 Connecting the SITRANS TF dual chamber housing 5. For devices with "Intrinsic safety" type of protection, use an isolating power supply that corresponds to the requirements of the relevant type of protection. ⑤ 6. Connect the input terminals 2-wire, 3-wire or 4-wire RTD or TC (internal CJC or linear resistance...
  • Page 42: Connecting The Sitrans Tf420 Dual Chamber Housing

    Connecting 4.6 Connecting the SITRANS TF dual chamber housing 4.6.3 Connecting the SITRANS TF420 dual chamber housing Procedure ① ⑤ Supply voltage Input terminals ② ⑥ HART communication resistor (optional) Protective conductor connector ③ ⑦ Cable gland Ground terminal ④ Test terminals Figure 4-3 Connecting the device...
  • Page 43 Connecting 4.6 Connecting the SITRANS TF dual chamber housing 5. For devices with "Intrinsic safety" type of protection, use an isolating power supply that corresponds to the requirements of the relevant type of protection. ⑤ 6. Connect the input terminals Input 1 (I1) and/or Input 1 (I1) and/or Input 1 (I1) and/or...
  • Page 44: Closing The Device

    Connecting 4.6 Connecting the SITRANS TF dual chamber housing 4.6.4 Closing the device Procedure ① ④⑤ Cover over buttons Cable gland ② ⑥ Cover (front) Cover (back) ③ ⑦ Safety catch (front) Safety catch (back) Figure 4-4 Closing the device ②...
  • Page 45: Connecting The Sitrans Tf Single Chamber Housing

    Connecting 4.7 Connecting the SITRANS TF single chamber housing Connecting the SITRANS TF single chamber housing 4.7.1 Opening the device Procedure ① Cover of the electrical cable compartment ② Safety catch Figure 4-5 Opening device with single chamber housing ② 1.
  • Page 46: Connecting The Sitrans Tf320 Single Chamber Housing

    Connecting 4.7 Connecting the SITRANS TF single chamber housing 4.7.2 Connecting the SITRANS TF320 single chamber housing Procedure 1. Remove the display from the holder. ① 2. Loosen the fastening screws of the temperature transmitter and remove it. ② 3. Lead the shielded connecting cables through the cable glands SITRANS TH320/TH420/TR320/TR420/TF320/TF420 Compact Operating Instructions, 03/2018, A5E41865021-AA...
  • Page 47 Connecting 4.7 Connecting the SITRANS TF single chamber housing ③ 4. Connect the shield to the screw of the ground terminal The screw of the ground terminal is electrically connected to the external protective conductor connection. 5. Insert the temperature transmitter and screw it in. ④...
  • Page 48: Connecting The Sitrans Tf420 Single Chamber Housing

    Connecting 4.7 Connecting the SITRANS TF single chamber housing 9. Screw the cover back on as far as it will go. ⑦ 10.Connect the device to the plant with the protective conductor connection 4.7.3 Connecting the SITRANS TF420 single chamber housing Procedure 1.
  • Page 49 Connecting 4.7 Connecting the SITRANS TF single chamber housing ② 3. Lead the shielded connecting cables through the cable glands ③ 4. Connect the shield to the screw of the ground terminal The screw of the ground terminal is electrically connected to the external protective conductor connection.
  • Page 50 Connecting 4.7 Connecting the SITRANS TF single chamber housing ④ ⑤ 6. Connect the input terminals and output terminals Connecting TH420 (Page 34) ⑥ Figure 4-6 HART communication resistor (optional) 7. For devices with "Intrinsic safety" type of protection, use an isolating power supply that corresponds to the requirements of the relevant type of protection.
  • Page 51: Closing The Device

    Connecting 4.7 Connecting the SITRANS TF single chamber housing 4.7.4 Closing the device Procedure ① Cover ② Safety catch ③ Cable gland Figure 4-7 Closing device with single chamber housing ① 1. Screw the cover back on as far as it will go. ②...
  • Page 52 Connecting 4.7 Connecting the SITRANS TF single chamber housing SITRANS TH320/TH420/TR320/TR420/TF320/TF420 Compact Operating Instructions, 03/2018, A5E41865021-AA...
  • Page 53: Commissioning

    Commissioning Basic safety notes WARNING Improper commissioning in hazardous areas Device failure or risk of explosion in hazardous areas. ● Do not commission the device until it has been mounted completely and connected in accordance with the information in Technical specifications (Page 65). ●...
  • Page 54: Commissioning Sitrans Th/Tr With Hart

    Commissioning 5.3 Commissioning SITRANS TH/TR with HART Procedure 1. If you want to change the factory settings, configure the device using the USB modem and the SIPROM T parameter assignment software. – Read the operating instructions for information on this. 2.
  • Page 55: Commissioning Sitrans Tf With 4

    Commissioning 5.4 Commissioning SITRANS TF with 4 ... 20 mA Procedure 1. Install/mount the device. Installing SITRANS TH in a connection head (Page 23) Installing SITRANS TH on DIN rail and G rail (Page 24) Installing SITRANS TR on DIN rail (Page 25) 2.
  • Page 56: Commissioning Sitrans Tf With Hart

    Commissioning 5.5 Commissioning SITRANS TF with HART 4. Switch on the power supply. Switching on the supply voltage (Page 57) 5. Wait for 2 seconds. After this start-up time, the device is operational. 6. Wait 5 minutes to get exact measured values. Commissioning SITRANS TF with HART Introduction In this section, you will learn how to commission the device step-by-step.
  • Page 57: Switching On The Supply Voltage

    Commissioning 5.6 Switching on the supply voltage Switching on the supply voltage Requirement ● You have connected the device correctly. (Page 31) ● The terminal voltage on the device is correct. (Page 65) Procedure Switch on the power supply. ● Product name and firmware version appear briefly on the display. ●...
  • Page 58 Commissioning 5.6 Switching on the supply voltage SITRANS TH320/TH420/TR320/TR420/TF320/TF420 Compact Operating Instructions, 03/2018, A5E41865021-AA...
  • Page 59: Service And Maintenance

    Service and maintenance Basic safety notes 6.1.1 Maintenance The device is maintenance-free. However, a periodic inspection according to pertinent directives and regulations must be carried out. An inspection can include check of: ● Ambient conditions ● Seal integrity of the process connections, cable entries, and cover screws ●...
  • Page 60: Cleaning

    Service and maintenance 6.2 Cleaning CAUTION Releasing button lock Improper modification of parameters could influence process safety. ● Make sure that only authorized personnel may cancel the button locking of devices for safety-related applications. NOTICE Penetration of moisture into the device Device damage.
  • Page 61: Maintenance And Repair Work

    6.3.1 SITRANS TF WARNING Impermissible repair and maintenance of the device ● Repair and maintenance must be carried out by Siemens authorized personnel only. WARNING Impermissible repair of explosion protected devices Risk of explosion in hazardous areas ● Repair must be carried out by Siemens authorized personnel only.
  • Page 62: Checking The Gaskets

    Incorrect measured values will be displayed. Changing the seals in a process flange of a differential pressure measuring cell can alter the start-of-scale value. ● Changing seals in devices with differential pressure measuring cells may only be carried out by personnel authorized by Siemens. Note Using the wrong seals Using the wrong seals with flush-mounted process connections can cause measuring errors and/or damage the diaphragm.
  • Page 63: Return Procedure

    Enclose the bill of lading, return document and decontamination certificate in a clear plastic pouch and attach it firmly to the outside of the packaging. Required forms ● Delivery note ● Return document (http://www.siemens.com/processinstrumentation/returngoodsnote) with the following information: – Product (item description) – Number of returned devices/replacement parts –...
  • Page 64 Service and maintenance 6.5 Disposal SITRANS TH320/TH420/TR320/TR420/TF320/TF420 Compact Operating Instructions, 03/2018, A5E41865021-AA...
  • Page 65: Technical Specifications

    Technical specifications Ambient conditions Ambient conditions SITRANS TH SITRANS TR SITRANS TF Ambient temperature range Standard -50 ... +85 °C (-58 ... +185 °F) -40 ... +80 °C (-40 ... +176 °F) Storage temperature -50 ... +85 °C (-58 ... +185 °F) Calibration temperature +24 °C (77 °F) ±1.0 °C (33.8 °F) Moisture...
  • Page 66: Common Specifications

    Technical specifications 7.3 Common specifications Common specifications General specifications SITRANS TH/TR SITRANS TF Supply voltage ... 48 V DC Single chamber housing Dual chamber housing ... 30 V DC (Ex i) Without display: Without display: 7.5 ... 48 V DC 8.2 ...
  • Page 67: Certificates And Approvals

    Technical specifications 7.4 Certificates and approvals Certificates and approvals 7.4.1 ATEX/IECEx and related ATEX/IECEx and others SITRANS TH/TR SITRANS TF Display Certificate number EN 60079-0:2012, DEKRA 17 ATEX 0116 X DEKRA xx ATEX xxxx X DEKRA xx ATEX xxxx U A11:2013, EN60079-11:2012 EN60079-15:2010,...
  • Page 68 Technical specifications 7.4 Certificates and approvals ATEX/IECEx and others SITRANS TH/TR SITRANS TF Display ГОСТ 31610.0-2014 № TC RU C– (IEC 60079-0:2011) DE.xxxx.x.xxxxxОС НАНИО ГОСТ «ЦСВЭ» 31610.1.1-2012 (IEC 60079-1:2002) ГОСТ xxxxx.xx-xxxx/ IEC 60079-31:2013 Zones 0, 1, 2, 20, 21, 22 and M1 ●...
  • Page 69 Technical specifications 7.4 Certificates and approvals ATEX/IECEx and others SITRANS TH/TR SITRANS TF Display Input terminals = 7.2 V DC, I = 12.9 mA, P = 23.3 mW, L = 200 mH, C 13.5 μF SITRANS TH/TF: 3, 4, 5, 6, 7, 8, 9 SITRANS TR: 5, 6, 7, 8, 9, 10, 11, 12 Zones 2 and 22...
  • Page 70 Technical specifications 7.4 Certificates and approvals ATEX/IECEx and others SITRANS TH/TR SITRANS TF Display Zones 2 and 22 ● "Non-sparking nA/ec" type of protection Take measures to ensure that the supply voltage (including transients) does not rise above 140% of the rated voltage. Name II 2 G Ex nA IIC T6 ...
  • Page 71 Technical specifications 7.4 Certificates and approvals ATEX/IECEx and others SITRANS TH/TR SITRANS TF Display Name II 2 G Ex db IIC T6 ... T4 Gb II 2 D Ex tb IIIC T100 °C Db ● ATEX Ex db IIC T6 ... T4 Gb ●...
  • Page 72: Fm/Csa

    Technical specifications 7.4 Certificates and approvals 7.4.2 FM/CSA FM/CSA SITRANS TH/TR SITRANS TF Display Certificate number FM-c FMxxCAxxxx FMxxUSxxxx CAN C22.2 No. 157-92: (affirmed 2012): CAN C22.2 No. 213-M1987: (af‐ firmed 2008): C22.2 No.30-M1986: (af‐ firmed 2012) C22.2 No. 1010.1:2004; CAN/ CSA-E60079-0:2011: CAN/CSA- E60079-11:2011:...
  • Page 73 Technical specifications 7.4 Certificates and approvals FM/CSA SITRANS TH/TR SITRANS TF Display Name IS,CL I, Div 1, GP ABCD, T6 ... T4 Ex ia IIC T6 … T4 Ga AEx ia IIC T6 … T4 Ga Ex ib [ia Ga] IIC T6 … T4 Gb AEx ib [ia Ga] IIC T6 …...
  • Page 74 Technical specifications 7.4 Certificates and approvals FM/CSA SITRANS TH/TR SITRANS TF Display Output terminals = 30 V DC, L = 0 μH, C 1.0 nF SITRANS TH/SI‐ TRANS TF single chamber housing: 1, 2 SITRANS TR: 3, 4 SITRANS TF dual chamber housing: (+) and (-) -50 …...
  • Page 75: Display

    Technical specifications 7.5 Display FM/CSA SITRANS TH/TR SITRANS TF Display -50 … +85 °C (-58 … +185 °F) ● Permissible temperature class T4 ambient -50 … +75 °C (-58 … +167 °F) temperature temperature class T5 -50 … +60 °C (-58 … +140 °F) temperature class T6 Input terminals = 7.2 V DC...
  • Page 76 Technical specifications 7.5 Display Display Decimal point change Automatically Error warning According to NAMUR NE 107 Electromagnetic compatibility According to DIN EN 61326-1 and NAMUR recom‐ mendation NE21 Construction Dimensions Diameter: 64.3 mm (2.53") Height: 15 ... 22.5 mm (0.6 ... 0.88") Installation Plug in Enclosure material...
  • Page 77: Technical Support

    In addition to our documentation, Siemens provides a comprehensive support solution at: ● Service&Support (http://www.siemens.com/automation/service&support) Personal contact If you have additional questions about the device, please contact your Siemens personal contact at: ● Partner (http://www.automation.siemens.com/partner) To find the personal contact for your product, go to "All Products and Branches" and select "Products &...
  • Page 78 Appendix A A.2 Certificates SITRANS TH320/TH420/TR320/TR420/TF320/TF420 Compact Operating Instructions, 03/2018, A5E41865021-AA...
  • Page 79: Index

    Index Modifications correct usage, 16 improper, 16 Article number, 12 Operating Instructions, 77 Certificates, 15, 77 Cleaning, 60 Compact Operating Instructions, 77 Customer Support, (Refer to Technical Support) Potentiometers, 9 Product name, 12 DC voltage sources, 9 DIN rail, 24, 25 QR code, 12 Disassembly, 29 Qualified personnel, 16...