CLOSE Command

Module Specific Syntax 3-6
7.023,025,027,029
7.034,057,110,151
7.004,033,034,035,036,037,038,039
END
This example shows that 5 include groups have been defined.
If the reply to this command takes more than 80 characters to
indicate a single include group, then the reply line will be
terminated with a semicolon before the carriage return and
linefeed. For example:
7.000,002,004,006,...,020,022;
7.022,024,026
This example indicates that the relays 022, 024, and 026 are on
the same include group as those on the previous reply line, since
the previous reply line was terminated with a semicolon.
The CLOSE command is used to close a channel.
Example:
CLOSE 7.002
This CLOSE command will close channel 2 of the module at
switch card module address 7.
Example:
CL 7.028-036
This CLOSE command will close channels 28 through 36 of the
module at switch card module address 7.
Example:
CL 7.066,071,072,073
This CLOSE command will close channels 66, 71, 72, and 73 of
the module at switch card module address 7.
Note that channels remain closed until one of the following occurs:
• an OPEN command is used to specifically open the relay
• a RESET command is executed, opening all relays
• a VXI Word Serial Clear command is received, opening all
User Manual 1260-18