Chapter 4: Maintenance; Service And Inspection Schedule; Cleaning And Lubrication - Aerotech ADRT Series Hardware Manual

Table of Contents

Advertisement

ADRT Hardware Manual

Chapter 4: Maintenance

The ADRT series stages are designed to require minimum maintenance.

4.1. Service and Inspection Schedule

D A N G E R : To minimize the possibility of bodily injury or death, disconnect all electrical
power prior to performing any maintenance or making adjustments to the equipment.
Inspect the ADRT at least once per month. A longer or shorter inspection interval may be required depending
on the specific application, and conditions such as the duty cycle, speed, and environment.
Monthly inspections should include but not be limited to:
Visually inspect the stage and cables.
l
Re-tighten loose connectors.
l
Replace or repair damaged cables.
l
Clean the ADRT and any components and cables as needed.
l
Repair any damage before operating the ADRT.
l
Inspect and perform an operational check on all safeguards and protective devices.
l
In general, repair and/or replacement of damaged or malfunctioning components by Aerotech field service
personnel is not possible. Repair typically requires that the unit be returned to the factory. Please contact
Aerotech Global Technical Support for more information.

4.2. Cleaning and Lubrication

There are no elements on ADRT stages that require lubrication.
The bearings, motors, and encoders for the ADRT series require no added lubrication or maintenance.
Periodic cleaning is recommended.
Before using a cleaning solvent on any part of the ADRT, blow away small particles and dust with nitrogen
or, less preferably, clean, dry, compressed air.
Any metal surface on the stage can be cleaned with either acetone or isopropyl alcohol.
www.aerotech.com
Chapter 4
Maintenance
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Adrt100Adrt150Adrt200Adrt260

Table of Contents