4.2
Configuring the signal output delay
The two rotary switches (potentiometers) on the DPDT relay electronics are
used for configuring delays of up to 30 seconds before the output signal
changes. This feature can help prevent false switching of outputs caused by
temporary movements of solids during filling or emptying operations.
By default, T1 and T2 are configured for 0 seconds (no delays).
Turning the T1 potentiometer clockwise increases the time delay for when
the output switches from a sensor covered -> free state.
Turning the T2 potentiometer clockwise increases the time delay for when
the output switches from free -> sensor covered.
Figure 4-2: Delay Settings
A. Potentiometer T1
B. Potentiometer T2