Solids level switch, vibrating fork
Hide thumbs Also See for Rosemount 2521:

Advertisement

Quick Start Guide
Light bulk materials
The signal output switches over when the forks of the level switch are
covered a few centimeters.
2.2
Mounting the level switch
Figure 2-4
Figure 2-4: Correct and Incorrect Mounting
A
B
H
A. Full-silo detection using the cable-extended fork length option
B. Empty-silo detection using the cable-extended or tube-extended fork
length option
C. Sliding sleeve option
D. Bulk solids slide downwards more easily when the device is mounted at
an angle (recommended)
E. Steel protection shield
F. Installation in the conical part is only suitable for solids material
(powder) that will not build-up on the forks
G. Incorrect installation - the fork orientation is not allowing solids material
to pass between the forks. Check the orientation mark on the hexagon is
either facing upwards or downwards
H. Incorrect installation - the socket is too long and allows the solids
material to easily accumulate inside it. The forks must protrude into the
silo sufficiently to correctly detect the level
14
shows how the level switch should be mounted.
C
A
B
OK
G
OK
D
E
F
October 2020