Part 4: Electrical Adjustments
• Temperature Correction
1) When Temperature Correction is
selected, the room temperature (as
measured by the Multiple Tool II or
HS-I/F) and the temperature mea-
sured by the camera will be displayed
as shown on the right. If the tempera-
ture difference between the room tem-
perature and camera's temperature
reading is 3°C or greater, press
Return to do the temperature correc-
tion.
2) The room temperature (as measured
by the Multiple Tool II or HS-I/F) will
be displayed. To correct this tempera-
ture in comparison with the current
room temperature, press the space
bar and enter the temperature with
the numeric keys. If it is OK, press
Return.
3) Press Return. After the transmission,
the screen on the right will appear. If
the difference between the room tem-
perature (as measured by the Multiple
Tool II or HS-I/F) and the temperature
measured by the camera is within
3°C, press Return. If it is greater than
3°C, press the space bar to correct it
again.
TEMP1
Temperature Correction
Match the camera's temperature reading
with the room temperature.
Room Temperature
25˚C
If the temperature difference is 3˚C or more,
correction is necessary.
To return to the menu, press the space bar.
TEMP2
Temperature Correction
Temperature correction will be executed.
Press Return to correct the camera's temperature
reading according to this temperature.
Press the space bar to change the room temperature.
Enter the temperature with the numeric keys.
Then press Return.
TEMP3
Temperature Correction
Room Temperature
25˚C
Check if the temperature difference is within 3˚C.
If it is OK, press Return.
If it is not OK,
press the space bar and do the correction again.
4-52
Camera
32˚C
Press Return.
Room Temperature
25˚C
Camera
26˚C

Advertisement