Installation

Setup

To avoid contaminating the fluid, pipe the exhaust
air to vent outside of the fluid product area, away
from people, animals, or food handling areas.
Note
Reference numbers and letters in
parentheses in the text refer to the callouts in
the figures and the parts drawings.
Accessories are available from Graco. Make certain
all accessories are sized and pressure rated to meet
your system requirements.
Figure 6 is only a guide for selecting and installing
system components and accessories. Contact your
Graco distributor for assistance in designing a system
to suit your particular needs.
1. Connect the master air supply to the 1/2 npt(f)
main air inlet valve (B). The incoming air pressure
maximum is 100 psi (0.7 MPa, 7 bar).
2. Verify that the elevator air supply connections (Y)
did not loosen during shipping.
3. Connect air tubing from the 1/2 npt(f)
push-to-connect fitting (X) to the pump air inlet
(D).
12
Springer Pumps, LLC
Telford, PA 18969
Air Controls
Figure 5
Key
B
R
S
T
U
V
W
X
Y
Tel: 866-777-6060 / Int'l: 215-949-2900
Fax: 866-777-6383 / Int'l: 215-721-1296
Main air inlet valve
Pump air pressure regulator
Pump air pressure gauge
Pump air switch, 2 position
Elevator air pressure regulator
Elevator air pressure gauge
Elevator director switch, 3 position
Air outlet to pump
Air outlet to elevator
333406A