Repair; Replace Elevator Seal - Graco SaniForce 24V310 Instructions - Parts Manual

Piston pump elevator packages
Hide thumbs Also See for SaniForce 24V310:
Table of Contents

Advertisement

Repair

Replace Elevator Seal

1. Remove the cap (122).
2. Screw the piston retainer capscrew (113) out of
the piston and remove the parts. Inspect parts
for wear and damage. Replace as necessary.
NOTE: When replacing packing (109), install a
new spreader (110) to increase the life of the
packing.
Apply medium-strength thread
sealant to the threads.
Torque to 20 to 40 ft-lb (27 to
54 N•m).
Torque to 15 to 20 ft-lb (20 to
27 N•m).
Apply appropriate waterproof
sanitary lubricant to the outside
of the leather packing.
Apply appropriate waterproof
sanitary lubricant.
333406A
Springer Pumps, LLC
Telford, PA 18969
3. Apply appropriate waterproof sanitary lubricant
4. Apply medium-strength thread sealant to the
Tel: 866-777-6060 / Int'l: 215-949-2900
Fax: 866-777-6383 / Int'l: 215-721-1296
to the inside surface of the tube. Reassemble in
reverse order.
internal threads of the piston housing (104) and
the threads of the capscrew (113). Torque the
capscrew to 15 to 20 ft-lb (20 27 N•m).
Repair
19
shop.springerpumps.com
info@springerpumps.com

Advertisement

Table of Contents
loading

Table of Contents