Installation; Choose A Location; Unpack The Equipment; Move Equipment To Location - Graco SaniForce 24V310 Instructions - Parts Manual

Piston pump elevator packages
Hide thumbs Also See for SaniForce 24V310:
Table of Contents

Advertisement

Installation

Choose a Location

Choose a location that meets the following
requirements:
• Is close to where the fluid is being delivered to
minimize back pressure and maximize flow rate.
• Provides enough room around the equipment for
maintenance.
• Provides enough room for access to the air supply
shutoff valves and the pneumatic controls.
• Provides enough room to load and unload fluid
drums, possibly four on a pallet, with a forklift or
hand truck.
• Has sufficient overhead clearance — 10 feet for
stationary models, 11 feet for mobile models.
• Has a flat, level floor.

Unpack the Equipment

Moving or installing the elevator components
without following these instructions may damage
the equipment.
1. Inspect the crate and boxes for shipping damage.
Contact the carrier if damaged.
2. Open all boxes. Mobile Models: Remove the
sides and top of the crate containing the cart.
3. Check the contents for loose or damaged parts.
4. Compare the packing slip against items inside the
boxes. Immediately call your Graco distributor
about any shortages or damage.
5. Remove the components from the boxes. Mobile
Models: Do not remove the cart from the pallet
at this time.
333406A
Springer Pumps, LLC
Telford, PA 18969
NOTICE
Tel: 866-777-6060 / Int'l: 215-949-2900
Fax: 866-777-6383 / Int'l: 215-721-1296

Move Equipment to Location

To avoid crushing injuries or muscle strains, never
have one person move or lift the elevator, the cart,
or the 6:1 or 12:1 pump.
Use a forklift or hand truck and support devices,
such as a hoist, and have an adequate number of
personnel to move the elevator, the cart, and the
larger pumps. Avoid jarring the equipment while
moving it.
NOTE:
• Ensure there is an adequate compressed air
supply. Refer to your pump manual for your air
consumption.
• Have the pump manual available.
• Ensure that all hoses are properly sized and
pressure rated for the system.

Assembly

1. Anchor the elevator.
Stationary Models: Use four 1/2–inch anchor
bolts (not supplied) to anchor the base plate of
the elevator to the floor. Follow hole pattern
shown.
10.0"
10.0"
Mobile Models: Lock the wheels on the cart. Use
four 1/2–13 x 1.25 in. bolts (9) to anchor the base
plate of the elevator to the cart.
Installation
4XØ 0.5"
9
shop.springerpumps.com
info@springerpumps.com

Advertisement

Table of Contents
loading

Table of Contents