Clean the Elevator and Pump

NOTE: The following instructions are a basic
procedure for cleaning a sanitary elevator.
• Be sure to follow your national and state sanitary
standard codes and local regulations.
• Use appropriate cleaning and disinfecting agents,
at intervals appropriate for product processed.
• Follow cleaning product manufacturer's
instructions.
1. Use the elevator to remove the pump from the
fluid container and place it in an empty drum.
Operate the pump to remove as much fluid as
possible.
2. Flush the system thoroughly with an appropriate
cleaning solution.
3. Remove the pump.
a. Disconnect the fluid hose.
b. Use the elevator to remove the pump from
the drum.
c. Stationary models: Remove the drum.
333406A
Springer Pumps, LLC
Telford, PA 18969
4. Clean external surfaces of the elevator and air

Shutdown

1. Follow the
2. Follow the pump shutdown instructions in your
Tel: 866-777-6060 / Int'l: 215-949-2900
Fax: 866-777-6383 / Int'l: 215-721-1296
Mobile models: Move the elevator to cleaning
location. Lower the elevator so the pump
rests on a clean, slightly raised surface.
d. Remove the clamp
e. Raise the elevator. The motor, tie rods, and
displacement rod will separate from the rest
of the pump.
f.
Remove all pump parts for cleaning, then
lower the elevator again.
Note: The pump must be disassembled
to clean it thoroughly. See your separate
pump manual for complete flushing and
cleaning procedures for a sanitary pump.
Any damaged rubber parts must be replaced
as they could harbor microorganisms that
can contaminate the fluid.
motor before reassembly.
Pressure Relief Procedure, page
separate pump manual.