Operation

Operation
Moving parts can pinch or crush your fingers or
hands. When raising or lowering the elevator,
keep fingers and hands away from the elevator,
articulating arm, drum cover, and the lip of the
drum. Do not operate the 5:1 or 6:1 pump without
tie rod guard in place. To quickly stop the lowering
of the ram, turn the director switch to UP.

Pressure Relief Procedure

Follow the Pressure Relief Procedure
whenever you see this symbol.
This equipment stays pressurized until pressure
is manually relieved. To help prevent serious
injury from splashing fluid or moving parts, follow
the Pressure Relief Procedure when you stop
dispensing and before cleaning, checking, or
servicing the equipment.
NOTE: Do not close the main air valve until Step 5.
The air controls will not operate when the main air
supply is in the off position.
1. Turn the pump air switch to OFF.
2. Open the fluid ball valve and/or dispensing valve
to relieve pump fluid pressure.
3. Set the elevator director switch to UP
the pump out of the drum, then remove drum.
4. Set the elevator director switch to DOWN.
The elevator will slowly lower all the way down.
Leave the director switch in the down position.
Do not put it into neutral.
14
Springer Pumps, LLC
Telford, PA 18969
5. Close the main air valve.

Flush Before First Use

The sanitary pump was assembled using sanitary
lubricant on moving parts and was tested in water.
Flush the pump thoroughly with an appropriate
cleaning solution or disassemble and sanitize the
parts before using the pump. See your separate
pump manual for complete flushing and cleaning
procedures for a sanitary pump. Check national,
state, and local codes for specific limitations.

Set Height of Articulating Arm

Adjust the height of the articulating arm and the pump
mounting bracket to meet the needs of your setup.
1. Close all air regulators and air valves.
2. Open the main air valve.
3. Set the elevator director switch to UP.
to lift
4. Stationary Models: Set an empty drum against
Tel: 866-777-6060 / Int'l: 215-949-2900
Fax: 866-777-6383 / Int'l: 215-721-1296
Slowly increase regulator pressure until the
elevator rises to its full height.
NOTE: Generally, 40 to 70 psi (0.3 to 0.48 MPa,
3 to 4.8 bar) is sufficient to raise the elevator.
the elevator base, under the pump.
Mobile Models: Move the cart into place by an
empty drum.
333406A