1. General information

Please read these instructions before installing the heat me-
ter. Kamstrup's guarantee obligations do not apply in case
of incorrect installation.
Please note the following installation requirements:
Gland meters
Max. 16 bar
1.1 MID designations
Rated operation conditions/measuring ranges:
Temperature of medium in flow sensor: 0.1°C...30°C
Mechanical environment: M1 (fixed installation with minimum
vibration)
Electromagnetic environment: E1 (Domestic and light indu-
strial). Signal cables from the meter must be separated by at
least 25 cm distance to other installations.
Climatic environment: The installation shall be made in non-
condensing environments and in closed location (indoor). The
ambient temperature must be within 5...55°C.
Maintenance and repair:
The water supplier is allowed to change communication module
and battery. The flow part must never be separated from the
calculator. All repairs require a following re-verification on an
accredited laboratory.
Battery for replacement: Kamstrup type 66-00-200-100.