TROUBLESHOOTING
If problems arise with the appliance, consult the following guide and try to resolve
them by implementing the suggestions provided. If the problems persist, contact Technical
Assistance. Do not carry out repairs directly on the appliance
The company Elektra declines any and all responsibility for tampering or interventions
carried out by non authorized persons.
Such intervention automatically renders the guarantee null and void.
The guide also contains problems that must be resolved directly by the Technical Assistance
Service but which are explained to facilitate comprehension and repair operations.
1

THE RED AND GREEN WARNING LIGHTS BLINKING

If the two warning lights flash simultaneously consult the first screen V1 on the smartphone
to find the specific alarm, as per the following paragraphs 1.1 - 1.2 - 1.3:

1.1 ALARM: BUFFER BATTERY ABOUT TO GO FLAT

This alarm is indicated by the icon:

1.2 BOILER WATER LEVEL CONTROL ALARM, FAULT

icon:
1.3 DISPENSING GROUP TEMPERATURE CONTROL ALARM, FAULT
icon:
2

THE MACHINE DOES NOT PRODUCE STEAM AND DOES NOT HEAT WATER

The machine was not supplied with water; the red warning light is on.
Fill the internal tank with water. Another possible cause is the activation of the electrical
protection of the boiler resistance.
The resistance must be replaced only after the cause of the fault has been removed
Contact Technical Assistance.