Counting Of The Coffee Production; Gather Of Drain Water; Protection Of The Heating Elements; Steam Boiler Heating Elements Protection - ELEKTRA SPF Instruction Manual

Espresso coffee machine 1gr
Table of Contents

Advertisement

12

COUNTING OF THE COFFEE PRODUCTION

The total number of coffees dispensed is displayed on the VP4 screen of the smartphone with the icon:
To reset, type the icon itself and confirm with:
13

GATHER OF DRAIN WATER

The machine is equipped with a removable lower cup holder with drain water gather tray.
If it is not connected to the drain outside, machine can be manually emptied; connecting it to
the external drain, removing the standard cap and fitting the tube present in the accessories
kit, the drain occurs automatically continuously.
14

PROTECTION OF THE HEATING ELEMENTS

14.1 STEAM BOILER HEATING ELEMENTS PROTECTION

This protection works by means of two thermal cutoff fuses integrated in the resistance itself
which are activated when the maximum allowable temperature is exceeded.
They irreversibly interrupt the power supply of the electrical resistance, which must then be
replaced after identifying the cause of the fault.

14.2 HEATING ELEMENTS PROTECTION OF DISPENSING GROUP BOILER

This protection works by means of two thermal cutoff fuses, fixed externally on the boiler,
which are activated when the maximum allowable temperature value is exceeded.
They irreversibly interrupt the power supply of the electrical resistance, which must then be
replaced after identifying the cause of the fault.
15

MEASURING THE BOILER PRESSURE

The appliance is fitted with a pressure gauge that displays the steam pressure in the boiler.
16

MEASURING THE BREWING PRESSURE

The appliance is equipped with a pressure gauge that displays the pressure delivered by
the pump during dispensing. By reading the value on the pressure gauge, it allows manual
adjustment of the pump pressure, working on a screw accessible from a hole positioned
below on the left side of the machine.
17

MEASURING THE WATER SUPPLY PRESSURE

The same pressure gauge described in the previous paragraph, when the pump is stopped
measures the pressure of the water supply that feeds the equipment.
14
(C12 2GO)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents