8-3) X, Y AXIS MOTOR DRIVE (SANYO)
① Y-axis driver
② X-axis driver
③ Power lamp
④ Rotary switch 1
⑤ Heat-proof plate
⑥ RESET switch
⑦ Cooling fan
• Rotary switch 1: Set X-driver at "C" and Y-driver at "F"
• Power lamp: green lights indicates normal and red lights indicates error
• RESET switch: when the power lamp turns red, press RESET to reset the driver
① SIGNAL 1: Signal cable connector
② AC IN: power connector (220V)
③ Motor: power connector for motor
④ FAN: power connector for cooling fan
⑤ Cooling fan
[FRONT]
[BACK]
8-4