Download Print this page

Maintenance & Trouble Shooting - Delta Elektronika EST150 Series Product Manual

Hide thumbs Also See for EST150 Series:

Advertisement

MAINTENANCE & TROUBLE SHOOTING
3.3.2 HUMIDITY
 During normal operation humidity will not harm the power
supply, provided the air is not aggressive. The heat normally
produced in the power supply will keep it dry.
 Condensation. Avoid condensation inside the power supply,
break-down could be the result. Condensation can occur
during a period the power supply is switched off (or operating
at no load) and the ambient temperature is increasing .
 Always allow the power supply to dry before switching it on
again.
3.3.3 GALVANIC INDUSTRY
 For using the power supplies in the galvanic industry it is
strongly recommended to take precautions against an
aggressive environment.
 An aggressive environment with acid, salt, etc. can harm the
electronic components. Sometimes even the copper traces of
the pc-boards dissolve.
 To avoid problems the power supplies should be mounted in
a relative clean room, or mounted in a cabinet receiving clean
air with over pressure. Or a cabinet with a heat exchanger.
4
MAINTENANCE & TROUBLE
SHOOTING
4.1
GENERAL
 The ES-series power supplies normally need no maintenance
or calibration. Only care must be taken that the cooling of the
unit is not obstructed.
4.2
NO OUTPUT (normal operation)
 Remove load from output.
 Check position of prog. switches at the rear panel, they
should be on MANUAL.
 Switch on unit.
 Turn all the CV and CC potentiometers a few turns clock-
wise. A voltage should be present on the output.
4.3
NO LEDS on.
 Overheating can be the cause, cooling down will reset the
thermal protection.
 Check input power.
 Check fuses inside unit.
4.4
NO equal voltages in Tracking Mode
 One or both of the tracking outputs are in CC mode (CC LED
on).
 Turn the CC potentiometers fully clockwise.
 Reduce the load.
7 / 9
DELTA ELEKTRONIKA B.V.
EST150
rev. Jan. 2021

Advertisement

loading