OPERATING MANUAL
PSC-232 module
PSC-232
PSC-232 P146
PSC-232 P148
PSC-488 module
PSC-488

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSC-232 module and is the answer not in the manual?

Questions and answers

Summary of Contents for Delta Elektronika PSC-232 module

  • Page 1 OPERATING MANUAL PSC-232 module PSC-488 module PSC-232 PSC-488 PSC-232 P146 PSC-232 P148...
  • Page 2: Table Of Contents

    Numerical data formats..................page 9 Installation of the PSC..................page 10 11.1 PSC-488 module..................page 10 11.2 PSC-488.......................page 10 11.3 PSC-232 module..................page 10 11.4 PSC-232, P146 or P148 ................page 11 Calibration of the PSC ..................page 11 12.1 Configuration setting ..................page 11 12.2 Voltage DAC Offset calibration ..............page 11 12.3...
  • Page 3 PSC SERIES DELTA ELEKTRONIKA BV 14.2.5 *CLS......................page 20 14.2.6 *ESE......................page 20 14.2.7 *ESR? ....................page 20 14.2.8 DSE......................page 21 14.2.9 DSR? ......................page 21 14.2.10 DSC? ......................page 22 14.2.11 DEE ......................page 22 14.2.12 DER? ......................page 22 14.2.13 DEC? ......................page 22 14.2.14 *OPC .......................page 23 14.2.15...
  • Page 4: Features

    DELTA ELEKTRONIKA BV PSC SERIES OP ER AT ING MAN UAL FOR POWER SUP PLY CON TROL LERS In ter nal PSC card Ex ter nal PSC mod ule Features The PSC is an RS232 or IEEE488 interface, designed for an analog programmable power supply.
  • Page 5: Accessories Supplied With The Psc

    • • • • CD ROM * = except in combination with SM3000 (Option P164 Dimensions PSC-488 module and PSC-232 module: 89 x 85.5 x 118 mm, 0.8 kg Enclosure: IP20 Specifications Dimensions PSC-232 and PSC-488 modules Power Ambient temperature...
  • Page 6: Analog Inputs

    Decimals Logic inputs 0 - 5.9999 6.000 - 59.999 The PSC-488 module and the PSC-232 module 60.000 - 599.99 provide two 1000 V opto isolated logic inputs, InpA and InpB for custom use. The inputs are 470 ohm, Logic high = 2.5 ... 8 V Example with power supply SM52-30: (15 mA max), Logic low = 0 V.
  • Page 7: Led Indicator

    PSC SERIES DELTA ELEKTRONIKA BV 6.10 Led indicator The PSC-232 module and the PSC-488 module have LEDs on the front panel. PSC-232 module PSC-488 module • • Power on • Listener mode • Talker mode • Device in error Device ready for •...
  • Page 8: Switch Settings

    DELTA ELEKTRONIKA BV PSC SERIES Switch settings Address switch When setting the address use any address from 1 up to 30. The address is a 5 bit binary number which can be set with switch A1 to A5. Switch A1 is the LSB and switch A5 is the MSB.
  • Page 9: Connections

    PSC SERIES DELTA ELEKTRONIKA BV Connections RS232 Interface Connector to next PSC: Connector from PC: D 9 M conn. D 9 F conn. Pin 2 Pin 2 Pin 3 Pin 3 9F Pole D connector 9M Pole D connector Pin 5 Pin 5 For connection to the PC or to the next PSC use a 1:1 cable with 1 female and 1 male connector.
  • Page 10: Conventions

    DELTA ELEKTRONIKA BV PSC SERIES Conventions Angle brackets < > Indicate that words or characters enclosed in angular brackets symbolize a program code parameter. Brackets { Brackets indicate one of the several parameters may be entered. For example { 1|0|ON|OFF}.
  • Page 11: Installation Of The Psc

    PSC SERIES DELTA ELEKTRONIKA BV Installation of the PSC When the External PSC module is used for the first time, it must be configured and calibrated together with the power supply. The card set types are factory configured and calibrated.
  • Page 12: Psc-232, P146 Or P148

    DELTA ELEKTRONIKA BV PSC SERIES 11.4 PSC-232, P146 or P148 These are card sets, mounted inside the power supply. Connect and install the PSC as follows: • Set the DIP switch to channel 1. A2, A3, A4, A5 = OFF and A1 = ON.
  • Page 13: Voltage Dac Gain Calibration

    PSC SERIES DELTA ELEKTRONIKA BV 12.3 Voltage DAC gain calibration • Switch the digital voltage meter to the right range (maximum output voltage of the power supply). • Click “Continue”. • Enter the DVM value. • Click “Continue”. • When calibration fails, repeat.
  • Page 14: Current Dac Gain Calibration

    DELTA ELEKTRONIKA BV PSC SERIES • Measure the shunt voltage with the D.V.M. and calculate the current. Enter the value. • Click “Continue”. • Click "Continue" to set the output to zero. • When calibration fails, repeat. • When calibration is successful, the program switches automatically to tab 6.
  • Page 15: Current Adc Gain Calibration

    PSC SERIES DELTA ELEKTRONIKA BV 12.9 Current ADC gain calibration • Switch the digital ampere meter to the right range. See “Set current”. • Click “Continue”. • Enter the DVM value. • Click “Continue”. • Check “Measure new current”. •...
  • Page 16: Power On Settings

    DELTA ELEKTRONIKA BV PSC SERIES Power on Settings When shipped, the PSC-488 module and the PSC-232 module are set to the configuration listed in table. All configurable parameters can be changed and stored by the user. Function Command Value Voltage range...
  • Page 17: Languages

    PSC SERIES DELTA ELEKTRONIKA BV Languages This section describes the operation of the three groups of commands. The Groups are: Delta Programming Languages DPL, Standard Commands Programmable Instruments SCPI, and Common commands. • Delta Programming commands is a PSC 44M compatible language. With the DIP switch A8 ON and A7 OFF the DPL is active.
  • Page 18: Ieee488.2 Common Commands

    DELTA ELEKTRONIKA BV PSC SERIES 14.2 IEEE488.2 Common Commands. The mnemonic common commands have three letters and begin with a star, the query commands are followed by a question mark (?). Common commands are defined by the IEEE STD 488.2-1987 standard and control status reporting, synchronization, power-on conditions and stored operating parameters of the PSC-488.
  • Page 19: Register Diagram

    PSC SERIES DELTA ELEKTRONIKA BV 14.2.3 Register diagram May 2008 MANUAL page 18...
  • Page 20: Stb

    DELTA ELEKTRONIKA BV PSC SERIES 14.2.4 *STB? The Read Status Byte Query reports the contents of the Status Byte Register. The register contains the summary status of all overlaying registers and status queues. When the Status Byte Register is read by a serial poll from the GPIB, the RQS bit is returned on bit position 6.
  • Page 21: Cls

    PSC SERIES DELTA ELEKTRONIKA BV 14.2.5 *CLS This Clear Status Command clears the device’s status structures. • All Event Registers summarized in the Status Byte. • The Standard Event Status Register. • Sets the device into the Operation Complete Command Idle State.
  • Page 22: Dse

    DELTA ELEKTRONIKA BV PSC SERIES Name Description of the standard Event Status Register Operation complete indicates whether an operation is completed or is still pending. Request Control Not implemented. Always set to 0. This error will occur when the Message Exchange Protocol is violated.
  • Page 23: Dsc

    PSC SERIES DELTA ELEKTRONIKA BV 14.2.10 DSC? The Device Status Condition register contains the power supply’s status, and returns a decimal value, which expressed in base 2, reflects the bit values of the Device Status. Execution of this query will not clear this register.
  • Page 24: Opc

    DELTA ELEKTRONIKA BV PSC SERIES 14.2.14 *OPC The Operation Complete Command allows for synchronization between a controller and several devices. It causes the instrument to set the Operation Complete Command -OPC- bit in the Standard Event Status Register to be set true when all selected pending operations have been finished. This implies that all device operations initiated by previous programming commands have been entirely completed or aborted.
  • Page 25: Idn

    PSC SERIES DELTA ELEKTRONIKA BV 14.2.16 *TST? The Self-Test Query causes the device to execute an internal self-test and reports detected errors. The PSC-488 will output the ASCII character 0 (20 hex) when the test is passed without failures. 14.2.17 *WAI The Wait-to-Continue Command is useful after an overlapped command to force sequential execution.
  • Page 26: Scpi Commands

    DELTA ELEKTRONIKA BV PSC SERIES 14.3 SCPI commands 14.3.1 SOurce:VOltage:MAximum 14.3.2 SOurce:CUrrent:MAximum These commands are used to enter the maximum voltage and maximum current range of the used power supply. For example, the Delta power supply model SM35-45 has a range of 35 volt and 45 ampere.
  • Page 27: Calibration:voltage:measure:offset

    PSC SERIES DELTA ELEKTRONIKA BV 14.3.11 CAlibration:VOLTage:MEASure:OFFSet Used to calibrate the zero-offset of the voltage monitoring. CAlibration:VOltage:MEASure:OFfset? Reads-back the present offset calibration value of the voltage monitoring. 14.3.12 CAlibrate:VOltage:MEasure:GAin Used to calibrate the full-scale of the voltage monitoring. CAlibrate:VOltage:MEasure:GAin? Reads-back the present full scale calibration value of the voltage monitoring.
  • Page 28: Source:function:rsd

    DELTA ELEKTRONIKA BV PSC SERIES 14.3.14 SOurce:FUnction:RSD<wsp><boolean> The command SOurce:FUnction:RSD<wsp>{ON|1}or abbreviated SO:FU:RSD<wsp>{ON|1} disables the output of the power supply. The command SOurce:FUnction:RSD<wsp>{OFF|0}or abbreviated SO:FU:RSD<wsp>{OFF|0} enables the output again. SOurce:FUnction:RSD? The query SOurce:FUnction:RSD? or abbreviated SO:FU:RSD? returns 1 when the power supply is disabled.
  • Page 29: Remote:cv

    PSC SERIES DELTA ELEKTRONIKA BV REMote? The query REMote? returns 0 when the power-supply in local mode. and in remote mode, a 1 is returned. LOCal Warning: After the command LOCal, the power supply will return to the potentiometers settings on the front panel.
  • Page 30: Source:voltage

    PSC-232xxx type with that channel number. Each unit must have a unique channel number between 0 and 30. The channel can be set with the DIP switch on the front panel of the PSC-232 module or on the back side of an power supply.
  • Page 31 PSC SERIES DELTA ELEKTRONIKA BV 14.3.29 CU With the CU command you can change the custom string of the identity string. See chapter 14.2.20. The string must have 15 characters including the <lf> and is send via RS232. Some examples: CU<WSP>CAL.
  • Page 32: Error Numbers

    DELTA ELEKTRONIKA BV PSC SERIES Error numbers There are four groups of standardized errors, which are reported in the Standard Event Status and in the Error/Event Queue, namely: Standard Event Classification Register Command Error bit 5 - CME Execution Error...
  • Page 33: Software Examples And Programs

    PSC SERIES DELTA ELEKTRONIKA BV Illegal password Invalid character Not connected with PSU Command not support, wrong configuration Software examples and programs Files on CD ROM or web site: • Datasheet • Manual • RS232 and GPIB Calibration Program •...