DELTA ELEKTRONIKA B.V. Vissersdijk 4, 4301 ND www.DeltaPowerSupplies.com DC POWER SUPPLIES Zierikzee, the Netherlands Tel. +31 111 413656 ES300–series ES 030-10 Product Manuals and Driver & Example Software For several Applications, build-in Options and Interfaces there are Application Notes, separate Product Manuals and Driver & Example Software available on our website.
Failure to comply with the safety precautions or warnings in this document violates safety standards of design, manufacture and intended use of this equipment and may impair the built-in protections. Delta Elektronika shall not be liable for user’s failure to comply with these requirements.
Page 3
Unscrew the screws and remove the cover(s). Always place the cover(s) back before connecting the unit to the mains supply again. 1.10 Environmental Conditions The Delta Elektronika power supplies safety approval applies to the following operating conditions: Indoor use ...
– DC power selected at the rear panel. 2.10 Ethernet / IEEE488 / RS232 PROGRAMMING The Delta Elektronika PSC-ETH and PSC-232 controllers can be built inside the unit. The programming connector on the Warning! 0Vprog. and Minus DC power power supply is compatible with the external interface PSC- are internally connected.
Page 5
CC status output, logic 1 = CC mode (5V / 4mA) Remote Shuntdown (+5V / 1mA) +12V output (Ri=500 Ohm) 0, return of status outputs, +12V and Remote Shuntdown. fig 2-8 Connections analog programming connector 5 / 13 DELTA ELEKTRONIKA B.V. rev. Sept. 2019...
Page 6
For long life the temperature of the air entering the unit, should be below 35 °C under normal conditions. Under extreme conditions it should be below 50 °C. 6 / 13 DELTA ELEKTRONIKA B.V. rev. Sept. 2019...
Page 7
Note: M/S parallel operation is not recommended for more than 4 units, consult factory for a solution. 2.28 POTENTIOMETERS CV and CC potentiometers with knobs at front panel. 7 / 13 DELTA ELEKTRONIKA B.V. rev. Sept. 2019...
ADAPTER must be used. With this adapter the master can be the upper or lower unit which, in particular for high voltages is 0Vprog. – DC power Warning! 0Vprog. and Minus DC power are internally connected. 8 / 13 DELTA ELEKTRONIKA B.V. rev. Sept. 2019...
Page 9
To avoid problems the power supplies should be mounted in a relative clean room, or mounted in a cabinet receiving clean air with over pressure. Or in a cabinet with a heat exchanger. 9 / 13 DELTA ELEKTRONIKA B.V. rev. Sept. 2019...
Check link between pin 9 and 11 on the programming connector of the slaves. NO LEDS on. Overheating can be the cause, cooling down will reset the thermal protection. Check input power. Check fuses inside unit. 10 / 13 DELTA ELEKTRONIKA B.V. rev. Sept. 2019...
– and S– (see fig. 5 - 3). MASTER / SLAVE PARALLEL PROBLEMS Current sharing is not ok. Probably the links between S– and – of the slaves are not removed. 11 / 13 DELTA ELEKTRONIKA B.V. rev. Sept. 2019...
Page 12
With the PSC-ETH the voltage and current can easily be programmed and read back. Also all the status outputs can be read by the computer. See PSC-ETH manual for further details. 12 / 13 DELTA ELEKTRONIKA B.V. rev. Sept. 2019...
EU DECLARATION ES300 DELTA ELEKTRONIKA B.V. Vissersdijk 4, 4301 ND www.DeltaPowerSupplies.com DC POWER SUPPLIES Zierikzee, the Netherlands Tel. +31 111 413656 EU Declaration of Conformity - ES300-series Delta Elektronika Vissersdijk 4 4301 ND ZIERIKZEE The Netherlands Declare under sole responsibility that the following Power Supplies:...
Need help?
Do you have a question about the ES300 Series and is the answer not in the manual?