DELTA ELEKTRONIKA B.V. Vissersdijk 4, 4301 ND www.DeltaPowerSupplies.com DC POWER SUPPLIES Zierikzee, the Netherlands Tel. +31 111 413656 ES150–series ES 015-10 ES 030-5 ES 075-2 ES 0300-0.45 Product Manuals and Driver & Example Software For several Applications, build-in Options and Interfaces there are Application Notes, separate Product Manuals and Driver &...
Failure to comply with the safety precautions or warnings in this document violates safety standards of design, manufacture and intended use of this equipment and may impair the built-in protections. Delta Elektronika shall not be liable for user’s failure to comply with these requirements.
Page 3
Unscrew the screws and remove the cover(s). Always place the cover(s) back before connecting the unit to the mains supply again. 1.10 Environmental Conditions The Delta Elektronika power supplies safety approval applies to the following operating conditions: Indoor use ...
0Vprog. 2.10 Ethernet / IEEE488 / RS232 PROGRAMMING The Delta Elektronika PSC-ETH and PSC-232 controllers can be built inside the unit. The programming connector on the – DC power power supply is compatible with the external interface PSC- 488 module.
Page 5
This is caused by the output capacitors, which can only be discharged by the load because the power supply cannot sink current. 5 / 13 DELTA ELEKTRONIKA B.V. rev. Sept. 2019...
Page 6
For long life the temperature of the air entering the unit, should be below 35 °C under normal conditions. Under extreme conditions it should be below 50 °C. 6 / 13 DELTA ELEKTRONIKA B.V. rev. Sept. 2019...
Page 7
4 units, consult factory for a solution. 2.28 POTENTIOMETERS 2.28.1 STANDARD CV and CC potentiometers with knobs at front panel. 2.28.2 Option P001 Screwdriver adjustment for CV and CC at the front panel. 7 / 13 DELTA ELEKTRONIKA B.V. rev. Sept. 2019...
ADAPTER must be used. With this adapter the master can be the upper or lower unit which, in particular for high voltages is 0Vprog. – DC power Warning! 0Vprog. and Minus DC power are internally connected. 8 / 13 DELTA ELEKTRONIKA B.V. rev. Sept. 2019...
Page 9
To avoid problems the power supplies should be mounted in a relative clean room, or mounted in a cabinet receiving clean air with over pressure. Or in a cabinet with a heat exchanger. 9 / 13 DELTA ELEKTRONIKA B.V. rev. Sept. 2019...
Check link between pin 9 and 11 on the programming connector of the slaves. NO LEDS on. Overheating can be the cause, cooling down will reset the thermal protection. Check input power. Check fuses inside unit. 10 / 13 DELTA ELEKTRONIKA B.V. rev. Sept. 2019...
– and S– (see fig. 5 - 3). MASTER / SLAVE PARALLEL PROBLEMS Current sharing is not ok. Probably the links between S– and – of the slaves are not removed. 11 / 13 DELTA ELEKTRONIKA B.V. rev. Sept. 2019...
Page 12
See PSC-ETH manual for further details. LOW OVL SETTING for the ES 75-2 OPTION P173 For this option the Over Voltage Limit (OVL) has been set below 60 V. 12 / 13 DELTA ELEKTRONIKA B.V. rev. Sept. 2019...
EU DECLARATION ES150 DELTA ELEKTRONIKA B.V. Vissersdijk 4, 4301 ND www.DeltaPowerSupplies.com DC POWER SUPPLIES Zierikzee, the Netherlands Tel. +31 111 413656 EU Declaration of Conformity - ES150-series Delta Elektronika Vissersdijk 4 4301 ND ZIERIKZEE The Netherlands Declare under sole responsibility that the following Power Supplies:...