Installation Instructions Kemlan Three Sided Natural Draft
ASSEMBLY REQUIREMENTS
IMPORTANT: BOTH
CAPS NEEDS TO STAY
OFF, IF HEAT ZONE IS
NOT USED
WALL LINING BY
INSTALLER
(ALL SIDES)
IMPORTANT: VENTILATION INTO
CHASE FROM VENT (SUPPLIED)
NOTE: VENT 240MM X 90MM
CAN ALSO BE INSTALLED ON THE
SIDE WALLS AS AN OPTION.
25/02/2021
Electronic Ignition Gas Fireplaces
Important: Both caps to stay off if heatzone is
not used.
Important: If a heatzone kit with fan is used, the
unsused outlet must remain uncapped
Ventilation Requirements:
Rooms with gas open fireplaces require fresh air
vents according to clause 6.4.4 in AS/NZS5601.
Ventilation size can be altered depending on the
appliances Mj usage Vs the total room size the
appliance is situated m3, this will be determined by a
licensed gas fitter.
NOTE: The chimney in which the appliance is installed
is not to be considered as a ventilation opening.
: THREE SIDED MODEL SHOWN
Ver. 1
DOUBLE SKIN FLUE
(SIZES VARY DUE TO
MODEL )
CEILING
COMBUSTIBLE
FRAMING