Kemlan Horizon 700 Low Line Installation Instructions Manual page 21

Three sided natural draft electronic ignition gas fireplaces
Hide thumbs Also See for Horizon 700 Low Line:
Table of Contents

Advertisement

Installation Instructions Kemlan Three Sided Natural Draft
Trouble shooting guide for Techrite ignition pack
Warning:
This is a 240VAC module. All connections to the module are 240V (except ignition cable and
flame sense). Ensure power is switched off before checking any connection or replacing any
components.
There is a red LED (light) and a green LED (light) on the blue ignition box. If a fault occurs the sequence
of the flashing red light indicates the fault. These codes are listed below.
The green light indicated the ignition box is sensing the flame
Atmospheric Models
Flash Code
(Red LED)
Long
short
1
0
2
1
2
2
Fan Forced Models
The codes above still apply plus the codes below
1
2
1
3
25/02/2021
Electronic Ignition Gas Fireplaces
Meaning
Running OK
Maximum retries
exceeded
Unit has tried to light
and not detected flame.
Flame fail lockout.
Unit has detected loss
of flame. It has tried
re-ignition and locked out
Pressure switch off
Pressure switch contacts.
have not closed.
Pressure switch on
Pressure switch contacts
have not opened after
last heat cycle.
.
Possible Cause
Appliance running correctly
(Green LED will be on)
Check spark electrode for damage
and clean if necessary. Check
electrode connection. Check
solenoid connections. Check gas
supply.
Check electrode, lead
and connection. Check gas supply.
.
Check if fan starts. If fan
starts OK, check pressure switch.
Pressure switch is faulty
and is stuck on, or fan has
not turned off.
Ver. 1
21

Hide quick links:

Advertisement

Table of Contents
loading