Advantech SOM-5962 User Manual
Advantech SOM-5962 User Manual

Advantech SOM-5962 User Manual

Intel atom c3000 processor com express r3.0 type 7 module

Advertisement

Quick Links

User Manual
SOM-5962
Intel® Atom™ C3000 Processor
COM Express R3.0 Type 7
Module

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SOM-5962 and is the answer not in the manual?

Questions and answers

Summary of Contents for Advantech SOM-5962

  • Page 1 User Manual SOM-5962 Intel® Atom™ C3000 Processor COM Express R3.0 Type 7 Module...
  • Page 2 No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. Information provided in this manual is intended to be accurate and reliable. How- ever, Advantech Co., Ltd.
  • Page 3 Class I, Division 2, Groups A, B, C and D indoor hazards. Technical Support and Assistance Visit the Advantech website at http://support.advantech.com where you can find the latest information about the product. Contact your distributor, sales representative, or Advantech's customer service center for technical support if you need additional assistance.
  • Page 4 Before setting up the system, check that the items listed below are included and in good condition. If any item does not accord with the table, please contact your dealer immediately.  SOM-5962 CPU module  1 x Heatspreader (1960073944N001) SOM-5962 User Manual...
  • Page 5 The sound pressure level at the operator's position according to IEC 704-1:1982 is no more than 70 dB (A). DISCLAIMER: This set of instructions is given according to IEC 704-1. Advantech disclaims all responsibility for the accuracy of any statements contained herein.
  • Page 6 Serial Presence Detect – refers to serial EEPROM on DRAMs that has DRAM Module configuration information Trusted Platform Module, chip to enhance the security features of a com- puter system UEFI Unified Extensible Firmware Interface Watch Dog Timer SOM-5962 User Manual...
  • Page 7: Table Of Contents

    Figure 3.21Processor Configuration -2........35 Figure 3.22Processor Configuration -3........36 Figure 3.23CPU Thermal Configuration ........36 Figure 3.24CPU DFX Thermal Configuration ......37 Figure 3.25Miscellaneous Configuration ........37 Figure 3.26Wake On Lan Configuration ........38 Figure 3.27Server ME Configuration .......... 38 SOM-5962 User Manual...
  • Page 8 S/W Introduction & Installation..61 S/W Introduction ..................62 Driver Installation ..................62 4.2.1 Windows Driver Setup ..............62 4.2.2 Other OS..................62 Advantech iManager ................63 Appendix A Assignment......... 65 SOM-5962 Type 7 Pin Assignment............66 SOM-5962 User Manual viii...
  • Page 9 Table D.1: System I/O ports............76 DMA Channel Assignments ..............77 Table D.2: DMA Channel Assignments........77 Interrupt Assignments ................77 Table D.3: Interrupt Assignments..........77 1st MB Memory Map ................78 Table D.4: 1st MB Memory Map ..........78 SOM-5962 User Manual...
  • Page 10 SOM-5962 User Manual...
  • Page 11: Chapter 1 General Information

    Chapter General Information This chapter gives background information on the SOM-5962 CPU Computer on Module. Sections include:  Introduction  Functional Block Diagram  Product Specification...
  • Page 12: Introduction

    Ethernet demand. (SOM-5992 also has 10GBase-KR interfaces) SOM-5962 support PCIe gen3 x8, x4 and x2 and support up to 2 PCIe x8 by option. In addition, SOM-5962 offer 4pcs 260P SO-DIMM and dual Channel. Max- imum memory size up to 128 GB and memory speed up to 2400MHz DDR4.
  • Page 13: Functional Block Diagram

    Functional Block Diagram SOM-5962 User Manual...
  • Page 14: Product Specification

    0 / 1 General Purpose I/O 8 / 8 SMBus 1 / 1 1 / 1 Watchdog Timer 0 / 1 Speaker Out 1 / 1 External BIOS ROM Support 0 / 2 Reset Function 1 / 1 SOM-5962 User Manual...
  • Page 15 ECC)Maximum support 32G on each socket (Total 128GB) Support both ECC and no-ECC version. Two rugged SODIMMs are supported by option. Dual channels design, one is on both top side and the other on bottom side, total up to 64GB memory size. SOM-5962 User Manual...
  • Page 16  PCIe x8 and x4 SOM-5962 supports 1 PCIe x8 and 1 PCIe x4 by default, up to 2 PCIe x8.(by option if remove GbE) The PCIe x8 above is configurable to be PCIe x1, PCIe x4 and PCIe x1.
  • Page 17 SPI_CS0# to Carrier Board, SPI_CS1# to Module SPI_CS0# to Module, SPI_CS1# to Carrier Board Note! If system COMS is cleared, strongly suggest to go BIOS setup menu and load default setting at the first time boot up. SOM-5962 User Manual...
  • Page 18 LPC Wake: Can wake from DB5962 Wake1# test button. Support S4-->S0 Advantech S5 ECO Mode (Deep Sleep Mode) Advantech iManager provides additional feature to allow system enter a very low suspend power mode - S5 ECO mode. In this mode, Module will cut all power includ- ing suspend and active power into chipset and keep an on-module controller active.
  • Page 19 OS Support (duplicate with SW chapter) The mission of Advantech Embedded Software Services is to "Enhance quality of life with Advantech platforms and Microsoft Windows embedded technology." We enable Windows Embedded software products on Advantech platforms to more effectively support the embedded computing community. Customers are freed from the hassle of dealing with multiple vendors (Hardware suppliers, System integrators, Embedded OS distributor) for projects.
  • Page 20 In layout checklist, it will specify the layout con- strains and recommendations for trace length, impedance, and other necessary infor- mation during design. Please contact your nearest Advantech branch office or call for getting the design documents and further advance supports. SOM-5962 User Manual...
  • Page 21: Chapter 2 Mechanical Information

    Chapter Mechanical Information This chapter gives mechanical information on the SOM-5962 CPU Computer on Module. Sections include:  Board Information  Mechanical Drawing  Assembly Drawing...
  • Page 22: Board Information

    Board Information The figures below indicate the main chips on SOM-5962 Computer-on-Module. Please aware of these positions while designing your own carrier board to avoid mechanical issues, as well as designing thermal solution contact points for best ther- mal dissipation performance.
  • Page 23: Connector List

    Wafer 2.0mm 3P 90D(M)DIP 2001-WR-03-LF W/Lock Pin Name Fan Tacho-Input Fan Out Mechanical Drawing For more detail about 2D/3D models, please find on Advantech COM support service website http://com.advantech.com . Figure 2.3 Board Mechanical Drawing - Front SOM-5962 User Manual...
  • Page 24 Figure 2.4 Board Mechanical Drawing - Back Figure 2.5 Board Mechanical Drawing - Side SOM-5962 User Manual...
  • Page 25: Assembly Drawing

    Assembly Drawing These figures demonstrate the assembly order from thermal module, COM module to carrier board. Figure 2.6 Assembly Drawing There are 4 reserved screw holes for SOM-5962 to be pre-assembled with heat spreader. SOM-5962 User Manual...
  • Page 26: Cpu Package Design

    CPU package design Please consider the CPU and chip height tolerance when designing your thermal solution. F5= 2.929mm ±0.135mm (POST SMT STACKUP HEIGHT BASED ON LIMITED DATA FROM INTEL REFER- ENCE BOARD DESIGN) SOM-5962 User Manual...
  • Page 27: Chapter 3 Bios Operation

    Chapter BIOS Operation This chapter gives BIOS setup information for the SOM-5962 CPU Computer on Module. Sections include:  Introduction  Entering Setup  Hot / Operation Key  Exit BIOS Setup Utility...
  • Page 28: Entering Setup

    For example: Date and Time. The <F1> key allows you to display the General Help screen. Press the <F1> key to open the General Help screen. Load Previous Values. Ignore modified configures. Load Optimized Defaults. SOM-5962 User Manual...
  • Page 29: Main Setup

    Displays the BIOS vendor's kernel core version. Displays this BIOS supporting industry standards Compliancy No option compliance. Project Version No option Displays the project version of Advantech projects. Build Date and Time No option Displays this BIOS build date and time. SOM-5962 User Manual...
  • Page 30: Advanced Bios Features Setup

    3.1.2 Advanced BIOS Features Setup Select the Advanced tab from the SOM-5962 setup screen to enter the Advanced BIOS Setup screen. Users can select any item in the left frame of the screen, such as CPU Configuration, to go to the sub menu for that item. Users can display an Advanced BIOS Setup option by highlighting it using the <Arrow>...
  • Page 31  Device Select Select the device. TPM 2.0 will restrict support to TPM 2.0 devices. Auto will support both with the default set to TPM 2.0 devices if no found. TPM 2.0 devices will be enumerated. SOM-5962 User Manual...
  • Page 32 If this feature is enabled as auto, no more Configuration Enable options can be configured. Enable or disable system’s ability to hibernate Disable Enable Hibernation (operating system S4 sleep state). Needs OS Enable support for this feature. SOM-5962 User Manual...
  • Page 33  Power Saving Mode Select ITE8518 Power Saving Mode  Serial Port 1 Configuration Set Parameters of Serial Port 3  Serial Port 2 Configuration Set Parameters of Serial Port 4  Hardware Monitor Monitor hardware status SOM-5962 User Manual...
  • Page 34  Serial Port 1 Configuration Figure 3.7 Serial Port 1 Configuration – Serial Port Enable or Disable Serial Port (COM) – Change Settings Select an optimal setting for Super IO device. SOM-5962 User Manual...
  • Page 35  Serial Port 2 Configuration Figure 3.8 Serial Port 2 Configuration – Serial Port Enable or Disable Serial Port (COM) – Change Settings Select an optimal setting for Super IO device. SOM-5962 User Manual...
  • Page 36  Hardware Monitor Figure 3.9 Hardware Monitor  Hardware Monitor Information This item shows Hardware information parameters. SOM-5962 User Manual...
  • Page 37 COM1 Console Redirection Console Redirection enable or disable  COM2 Console Redirection Console Redirection enable or disable  Serial Port for Out-of-Band Management / Windows Emergency Manage- ment Service (EMS) Console Redirection Console Redirection Enable or Disable SOM-5962 User Manual...
  • Page 38  PERR# Generation Enable or Disable PERR# Generation  SERR# Generation Enable or Disable SERR# Generation  Above 4G Decoding Enable or Disable Above 4G Decoding  SR-I0V Support:  BME DMA Mitigation  PCI Express Setting SOM-5962 User Manual...
  • Page 39 Figure 3.12 PCI Express Setting  PCIE 2.0 device Register Setting Figure 3.13 PCIE 2.0 device Register Setting SOM-5962 User Manual...
  • Page 40  Network Stack Enable or Disable Network Stack  Ipc4 PXE Support Enable or Disable Ipv4 PXE Support.  Ipv6 PXE Support Enable or Disable Ipv6 PXE Support.  PXE boot wait time  Media detect count SOM-5962 User Manual...
  • Page 41 Storage Controls the execution of UEFI and legacy storage OpROM  Video Controls the execution of UEFI and legacy video OpROM  Other PCI devices Determines OpROM execution policy for devices other than network, storage, or video SOM-5962 User Manual...
  • Page 42 Maximum time the device will take before it properly reports itself to the Host Controller. ‘Auto’ uses default value: for a Root port it is 100 ms, for a Hub port the delay is taken from Hub descriptor. SOM-5962 User Manual...
  • Page 43: Intelrc Setup

    3.1.3 IntelRC Setup Select the IntelRCSetup tab from the SOM-5962 setup screen to enter the BIOS Setup screen. You can select the items by highlight¬ing it using by the <Arrow> keys. All Plug and Play BIOS Setup options are described in this section. The Plug and Play BIOS Setup screen is shown below.
  • Page 44 3.1.3.1 Fia Mux Configuration Figure 3.18 Fia Mux Configuration_1 Figure 3.19 Fia Mux Configuration_2 SOM-5962 User Manual...
  • Page 45 3.1.3.2 Processor Configuration Figure 3.20 Processor Configuration -1 Figure 3.21 Processor Configuration -2 SOM-5962 User Manual...
  • Page 46 Figure 3.22 Processor Configuration -3 3.1.3.3 CPU Thermal Configuration Figure 3.23 CPU Thermal Configuration SOM-5962 User Manual...
  • Page 47 Figure 3.24 CPU DFX Thermal Configuration 3.1.3.4 Miscellaneous Configuration Figure 3.25 Miscellaneous Configuration SOM-5962 User Manual...
  • Page 48 3.1.3.5 Wake On Lan Configuration Figure 3.26 Wake On Lan Configuration 3.1.3.6 Server ME Configuration Figure 3.27 Server ME Configuration  Altitude  MCTP Bus Owner SOM-5962 User Manual...
  • Page 49  ME Shutdown Message  ICC Clock SSC 3.1.3.7 System Event Log Figure 3.28 System Event Log Memory Event Log Figure 3.29 Memory Event Log SOM-5962 User Manual...
  • Page 50 PCIe Event Log Figure 3.30 PCIe Event Log Whea Settings Figure 3.31 Whea Settings SOM-5962 User Manual...
  • Page 51 3.1.3.8 North Bridge Chipset Configuration Figure 3.32 North Bridge Chipset Configuration_1 Figure 3.33 North Bridge Chipset Configuration_2 SOM-5962 User Manual...
  • Page 52 Figure 3.34 North Bridge Chipset Configuration_3  Pass Gate Setup Figure 3.35 Pass Gate Setup_1 SOM-5962 User Manual...
  • Page 53 Figure 3.36 Pass Gate Setup_2  Leaky Bucket Setup Figure 3.37 Leaky Bucket Setup_1 SOM-5962 User Manual...
  • Page 54 Figure 3.38 Leaky Bucket Setup_2  Method Figure 3.39 Method SOM-5962 User Manual...
  • Page 55  Memory Configuration Figure 3.40 Memory Configuration  Timing Configuration Figure 3.41 Timing Configuration SOM-5962 User Manual...
  • Page 56  SSA Config Figure 3.42 SSA Config  DFX SSA Config Figure 3.43 DFX SSA Config_1 SOM-5962 User Manual...
  • Page 57 Figure 3.44 DFX SSA Config_2  Processor DFX Configuration Figure 3.45 Processor DFX Configuration_1 SOM-5962 User Manual...
  • Page 58 Figure 3.46 Processor DFX Configuration_2  PPR Sequence Figure 3.47 PPR Sequence SOM-5962 User Manual...
  • Page 59 3.1.3.9 South Bridge Chipset Configuration Figure 3.48 South Bridge Chipset Configuration  SATA Configuration Figure 3.49 SATA Configuration_1 SOM-5962 User Manual...
  • Page 60 Figure 3.50 SATA Configuration_2 Figure 3.51 SATA Configuration_3 SOM-5962 User Manual...
  • Page 61  USB Configuration Figure 3.52 USB Configuration_1 Figure 3.53 USB Configuration_2 SOM-5962 User Manual...
  • Page 62 Figure 3.54 USB Configuration_3  PCIE IP Configuration Figure 3.55 PCIE IP Configuration_1 SOM-5962 User Manual...
  • Page 63 Figure 3.56 PCIE IP Configuration_2 Figure 3.57 PCIE IP Configuration_3 SOM-5962 User Manual...
  • Page 64  IQAT Configuration Figure 3.58 IQAT Configuration 3.1.4 Server Mgmt Select the Server Mgmt tab from the SOM-5962 setup screen to Enable or disable interface to communicate with BMC. Figure 3.59 Server Mgmt SOM-5962 User Manual...
  • Page 65 3.1.5 Event Logs Figure 3.60 Event Logs Figure 3.61 Smbios Event Logs SOM-5962 User Manual...
  • Page 66 Figure 3.62 Log Area Reset SOM-5962 User Manual...
  • Page 67 3.1.6 Security Select the Security tab from the SOM-5962 setup screen to enter the BIOS Setup screen. You can select the items by highlight¬ing it using by the <Arrow> keys. All Plug and Play BIOS Setup options are described in this section. The Plug and Play BIOS Setup screen is shown below.
  • Page 68 Figure 3.65 Provision Factory Default 3.1.7 Boot Select the Boot tab from the SOM-5962 setup screen to enter the BIOS Setup screen. You can select the items by highlighting it using by the <Arrow> keys. Figure 3.66 Boot SOM-5962 User Manual...
  • Page 69 BIOS setup menu and reboot the computer to take effect all system configuration parameters.  Discard Changes and Reset Select this option to quit Setup without making any permanent changes to the system configuration and reboot the computer. SOM-5962 User Manual...
  • Page 70  Restore Defaults The SOM-5962 automatically configures all setup items to optimal settings when users select this option. Optimal Defaults are designed for maximum system perfor- mance, but may not work best for all computer applications. In particular, do not use the Optimal Defaults if the user's computer is experiencing system configuration problems.
  • Page 71 Chapter S/W Introduction & Installation Sections include:  S/W Introduction  Driver Installation  Advantech iManager...
  • Page 72 S/W Introduction The mission of Advantech Embedded Software Services is to "Enhance quality of life with Advantech platforms and Microsoft Windows embedded technology." We enable Windows Embedded software products on Advantech platforms to more effectively support the embedded computing community. Customers are freed from the hassle of dealing with multiple vendors (Hardware suppliers, System integrators, Embedded OS distributor) for projects.
  • Page 73 More details of how to use the APIs and utilities, please refer to the Advantech iManager 2.0 Software API User Manual. SOM-5962 User Manual...
  • Page 74 SOM-5962 User Manual...
  • Page 75 Appendix Pin Assignment This appendix gives you the infor- mation about the hardware pin assignment of the SOM-5962 CPU System on Module. Sections include:  SOM-5962 Type 7 Pin Assign- ment...
  • Page 76 This section gives SOM-5962 pin assignment on COM Express connector which compliant with COM Express R3.0 Type 7 pin-out definitions. More details about how to use these pins and get design reference. Please contact to Advantech for design guide, checklist, reference schematic, and other hardware/software supports.
  • Page 77 PCIE_RX1- WAKE0# GPI2 WAKE1# PCIE_TX0+ PCIE_RX0+ PCIE_TX0- PCIE_RX0- GND(FIXED) GND(FIXED) GND(FIXED) GND(FIXED) NCSI_TX_EN VCC_5V_SBY GPI3 VCC_5V_SBY RSVD VCC_5V_SBY RSVD VCC_5V_SBY PCIE_CLK_REF+ BIOS_DIS1# PCIE_CLK_REF- GND(FIXED) GND(FIXED) SPI_POWER NCSI_CLK_IN SPI_MISO NCSI_RXD1 GPO0 NCSI_RXD0 SPI_CLK NCSI_CRS_DV SPI_MOSI NCSI_TXD1 TPM_PP NCSI_TXD0 SOM-5962 User Manual...
  • Page 78 A105 VCC_12V B105 VCC_12V A106 VCC_12V B106 VCC_12V A107 VCC_12V B107 VCC_12V A108 VCC_12V B108 VCC_12V A109 VCC_12V B109 VCC_12V A110 GND(FIXED) B110 GND(FIXED) SOM-5962 ROW C, D GND(FIXED) GND(FIXED) USB_SSRX0- USB_SSTX0- USB_SSRX0+ USB_SSTX0+ USB_SSRX1- USB_SSTX1- USB_SSRX1+ USB_SSTX1+ USB_SSRX2- USB_SSTX2-...
  • Page 79 PEG_RX2- PEG_TX2- GND(FIXED) GND(FIXED) PEG_RX3+ PEG_TX3+ PEG_RX3- PEG_TX3- RSVD RSVD RSVD RSVD PEG_RX4+ PEG_TX4+ PEG_RX4- PEG_TX4- RAPID_SHUTDOWN PEG_RX5+ PEG_TX5+ PEG_RX5- PEG_TX5- GND(FIXED) GND(FIXED) PEG_RX6+ PEG_TX6+ PEG_RX6- PEG_TX6- PEG_RX7+ PEG_TX7+ PEG_RX7- PEG_TX7- RSVD RSVD GND(FIXED) GND(FIXED) RSVD RSVD SOM-5962 User Manual...
  • Page 80 D101 - C102 - D102 - C103 GND D103 GND C104 VCC_12V D104 VCC_12V C105 VCC_12V D105 VCC_12V C106 VCC_12V D106 VCC_12V C107 VCC_12V D107 VCC_12V C108 VCC_12V D108 VCC_12V C109 VCC_12V D109 VCC_12V C110 GND(FIXED) D110 GND(FIXED) SOM-5962 User Manual...
  • Page 81: Appendix B Watchdog Timer

    Appendix Watchdog Timer This appendix gives you the infor- mation about the watchdog timer programming on the SOM-5962 CPU System on Module. Sections include:  Watchdog Timer Programming...
  • Page 82: Programming The Watchdog Timer

    ** WDT new driver support automatically select available IRQ number from BIOS, and then set to EC. Only Win8.1 and Win10 support it. In other OS, it will still use IRQ number from BIOS setting as usual. For details, please refer to iManager & Software API User Manual: SOM-5962 User Manual...
  • Page 83: Appendix C Programming Gpio

    Appendix Programming GPIO This Appendix gives the illustra- tion of the General Purpose Input and Output pin setting. Sections include:  System I/O Ports...
  • Page 84: Gpio Register

    GPIO Register GPIO Byte Mapping H/W Pin Name BIT0 GPO0 BIT1 GPO1 BIT2 GPO2 BIT3 GPO3 BIT4 GPI0 BIT5 GPI1 BIT6 GPI2 BIT7 GPI3 For details, please refer to iManager & Software API User Manual. SOM-5962 User Manual...
  • Page 85: Appendix D System Assignments

    Appendix System Assignments This appendix gives you the infor- mation about the system resource allocation on the SOM-5962 CPU System on Module. Sections include:  System I/O ports  DMA Channel Assignments  Interrupt Assignments  1st MB Memory Map...
  • Page 86: System I/O Ports

    Intel® Atom™ processor C3000 product family PCIe Root Port 2 - 03B0-03BB 19A6 03B0-03BB PCI Express to PCI/PCI-X Bridge Intel® Atom™ processor C3000 product family PCIe Root Port 2 - 03C0-03DF 19A6 03C0-03DF PCI Express to PCI/PCI-X Bridge 03F8-03FF Communications Port (COM1) 04D0-04D1 Programmable interrupt controller SOM-5962 User Manual...
  • Page 87: Dma Channel Assignments

    Intel® USB 3.0 eXtensible Host Controller - 1.0 (Microsoft) IRQ 4294967208~ Intel® Ethernet Connection X553/X557-AT 10GBASE-T 4294967225 IRQ 4294967226~ Intel® Ethernet Connection X553/X557-AT 10GBASE-T #2 4294967243 IRQ 4294967244~ Intel® Ethernet Connection X553/X557-AT 10GBASE-T #3 4294967261 IRQ 4294967262~ Intel® Ethernet Connection X553/X557-AT 10GBASE-T #4 4294967279 SOM-5962 User Manual...
  • Page 88: 1St Mb Memory Map

    0xDFE00000-0xDFE03FFF 0xDF600000-0xDF7FFFFF Intel® Ethernet Connection X553/X557-AT 10GBASE-T 0xDF804000-0xDF807FFF 0xDF400000-0xDF8FFFFF Intel® Ethernet Connection X553/X557-AT 10GBASE-T 0xDF800000-0xDF803FFF 0xDC300000-0xDC37FFFF 0xDC380000-0xDC383FFF Intel® I210 Gigabit Network Connection 0xDC580000-0xDC58FFFF Intel® USB 3.0 eXtensible Host Controller - 1.0 (Microsoft) 0xFEC00000-0xFEC00FFF Advanced programmable interrupt controller SOM-5962 User Manual...
  • Page 89 0xFB000000-0xFB7FFFFF 0xFA100000-0xFA1007FF 0xFE010000-0xFE010FFF PCI Express Root Complex 0xA0000-0xBFFFF 0xDC400000-0xDC4FFFFF PCI Express Root Port 0xD8000000-0xDC0FFFFF PCI Express to PCI/PCI-X Bridge 0xA0000-0xBFFFF 0xDC594000-0xDC595FFF 0xDC59B000-0xDC59B0FF Standard SATA AHCI Controller 0xDC59A000-0xDC59A7FF 0xE0000000-0xEFFFFFFF 0x7FC00000-0x7FFFFFFF System board 0xFED60000-0xFED60FFF 0xFED40000-0xFED44FFF Trusted Platform Module 2.0 SOM-5962 User Manual...
  • Page 90 No part of this publication may be reproduced in any form or by any means, electronic, photocopying, recording or otherwise, without prior written permis- sion of the publisher. All brand and product names are trademarks or registered trademarks of their respective companies. © Advantech Co., Ltd. 2020...

Table of Contents