FLO-DYNAMICS C-VAC3 Complete Service & Maintenance Manual page 21

Coolant flush machine
Hide thumbs Also See for C-VAC3:
Table of Contents

Advertisement

FIGURE 3-8
Remove
FIGURE 3-9
Push White
Fitting
1. Remove bottom service panel using 1/8" hex-
head wrench. (
2. Remove pump mounting screws and move pump
forward for clearance (
3. Disconnect solenoid valve from vacuum
generator. Use 3/8" open-end wrench to push fitting
in (
4. Remove plastic fitting with 13/16" open-end
wrench.
5. Unscrew vacuum generator using 3/4 and 7/8
open ended wrenches.
6. Replace with new vacuum generator. Exploded
Parts View on Page 23.
NOTE: Be sure to apply thread-sealer to the
threads before replacing.
FIGURE 3-10
Remove
Vacuum Generator
Pg. 21)
Figure 3-7
).
Pg. 24
Figure 3-9
Figure 3-10
7/8"
)
3/4"
21