A. Has all field piping been leak tested at 150 psig (690 kPA)?
B. Has system been properly evacuated and charged?
C. Refrigerant R-
Circuit 1
D. Reviewed and confirmed piping is per the approved SF-99006 form submitted to the factory?
E. Is a liquid line filter-drier installed in each circuit?
F. Is a liquid line solenoid installed correctly in each circuit?
G. Is Expansion Valve and associated sensors installed, insulated and wired correctly?
(Including Entering water and Leaving water sensors.)
A. CHILLER
Water Pressure Drop:
Water Temperatures: Entering
B. CONDENSER
Design Ambient Temperatures: Entering
Minimum Ambient Temperatures: Entering
A. Does unit start and perform per sequence of operation as stated in the IOM Manual?
B. Do condenser fans rotate in the proper directions?
MICROTECH STATUS CHECK-Each Reading Must be Verified with Field Provided Instruments of Known Accuracy?
C. Water Temperatures:
D. Circuit #1 Refrigerant Pressures:
E. Circuit #2 Refrigerant Pressures:
F. Circuit #1 Refrigerant Temperatures:
SF-20001 AGZ/AMZ Start-Up 8/2020
IOM 1207-6 • TRAILBLAZER
REFRIGERANT PIPING FOR REMOTE EVAPORATOR APPLICATIONS
lbs (kg)
Circuit 2
DESIGN CONTROLS
psig(kPa)
Leaving
°F (°C)
Leaving Evaporator
....................................
Entering Evaporator
....................................
Evaporator
.................................................
Liquid Line pressure
.......................................................................
Condenser Pressure
....................................
Evaporator
.................................................
Liquid Line Pressure
......................................................................
Condenser Pressure
...................................
Saturated Evaporator Temperature
Suction Line Temperature .....................................
Suction Superheat ..............................................
Saturated Condenser Temperature ........................
Liquid Line Temperature
....................................................................
Subcooling
......................................................................................
Discharge Temperature
....................................................................
MODEL AGZ CHILLERS
®
Warranty Registration Form (Scroll)
lbs. (kg)
Ft. (kPa)
gpm (lps)
°F (°C)
°F (°C)
Leaving
°F (°C)
Leaving
START-UP
........................
3 of 8
140
N/A Yes
°F (°C)
°F (°C)
Yes No
MicroTech
Verification
°F (°C)
°F (°C)
°F (°C)
°F (°C)
psig (kPa)
psig (kPa)
psig (kPa)
psig (kPa)
psig (kPa)
psig (kPa)
psig (kPa)
psig (kPa)
psig (kPa)
psig (kPa)
°F (°C)
°F (°C)
°F (°C)
°F (°C)
°F (°C)
°F (°C)
°F (°C)
°F (°C)
°F (°C)
°F (°C)